beautypg.com

Vetter pneumatic hazmat container pab, Inspection, Taking the product out of operation – Vetter Pneum. collection containers User Manual

Page 6: Technical data

background image

Vetter Pneumatic Hazmat Container PAB

Page 5/6

5.

Inspection

The inflation fittings and the Hazmat Container are to be checked
for a perfect and orderly condition each time before and after
use:

9

The stiffening frame is free of damage, e.g. tears, cuts, pier-

cings, splits, hard or soft areas caused by chemical or thermal

effects.

9

The PVC foldable container is free of damage, e.g. tears, cuts,

piercings, splits, hard or soft areas caused by chemical or ther-

mal effects.

9

Visual and operational check of the pressure regulator

6.

Taking the product out of operation

In case the Pneumatic Hazmat Containers are taken out of ope-
ration then this must be disposed of as special waste. If required,
the manufacturer can supply you with more detailed information
regarding this.

7.

Technical data

Type

PAB 3000

PAB 5000

Art.-No. (set)

1510000101

1510004001

Size (internal) Ø

cm

225

280

inch

88

110

Size (external) Ø

cm

265

320

inch

104

126

Height

cm

95

95

inch

37

37

Operating pressure

bar

0.5

0.5

psi

7.25

7.25

Test pressure

bar

0.65

0.65

psi

9.4

9.4

Nominal content

l

470

562

cu.ft. 16.6

19.8

Air requirement

l

705

843

cu.ft. 25

30

Capacity

l

3,000

5,000

cu.ft. 106

177

Weight

kg

33

44

lbs

73

97

All rights reserved for technical changes within the scope of product improve-

ment.