Vetter pneumatic hazmat container pab, Inspection, Taking the product out of operation – Vetter Pneum. collection containers User Manual
Page 6: Technical data

Vetter Pneumatic Hazmat Container PAB
Page 5/6
5.
Inspection
The inflation fittings and the Hazmat Container are to be checked
for a perfect and orderly condition each time before and after
use:
9
The stiffening frame is free of damage, e.g. tears, cuts, pier-
cings, splits, hard or soft areas caused by chemical or thermal
effects.
9
The PVC foldable container is free of damage, e.g. tears, cuts,
piercings, splits, hard or soft areas caused by chemical or ther-
mal effects.
9
Visual and operational check of the pressure regulator
6.
Taking the product out of operation
In case the Pneumatic Hazmat Containers are taken out of ope-
ration then this must be disposed of as special waste. If required,
the manufacturer can supply you with more detailed information
regarding this.
7.
Technical data
Type
PAB 3000
PAB 5000
Art.-No. (set)
1510000101
1510004001
Size (internal) Ø
cm
225
280
inch
88
110
Size (external) Ø
cm
265
320
inch
104
126
Height
cm
95
95
inch
37
37
Operating pressure
bar
0.5
0.5
psi
7.25
7.25
Test pressure
bar
0.65
0.65
psi
9.4
9.4
Nominal content
l
470
562
cu.ft. 16.6
19.8
Air requirement
l
705
843
cu.ft. 25
30
Capacity
l
3,000
5,000
cu.ft. 106
177
Weight
kg
33
44
lbs
73
97
All rights reserved for technical changes within the scope of product improve-
ment.