2.4

Correct handling and usage

The Pneumatic Hazmat Container PAB is only allowed to be used
with compressed air. Only original Vetter inflation fittings are to be
used in order to avoid over-inflation of the Hazmat Container.

3.

Preparing the product for use

3.1

Preparations for operation

Only perfectly working Hazmat Containers are to be used having
original Vetter inflation fittings. Before being used, the chemical
resistance of the PVC foldable container is to be tested against the
liquid or substance to be collected.

4.

Operating instructions

Open the packing cover. Lay out the Pneumatic Hazmat Contai-
ner at the required location. The ground area must be free of any
sharp-edged or pointed objects!

4.1

Operation with compressed air

Connect the pressure regulator with the knurled wheel on the
compressed air bottle. Close the hand wheel (3) of the pressure
regulator. Open the valve on the bottle (5). The manometer (1)
indicates the pressure in the bottle. Adjust the back-pressure to
approximately 10 bar/145 psi using the adjustment wheel (4). The
set pressure can be checked on the back-pressure manometer (2).
Connect the air hose of the pressure regulator (6) with the brass
coupling (7) of the inflation connection. Open the pressure regu-
lator and start inflation. Observe the Pneumatic Hazmat Container
during the inflation process. Close the hand valve when the ope-
rating pressure of 0.5 bar/7.25 psi is reached.

The Vetter Pneumatic Hazmat Container is now operati-
onal.

Do not inflate outer frame! The valve is only
for air compensation when the container

is upright or folded.

4.2

Pumping off the collected fluid

To pump off the collected fluid, use a commercially availab-
le immersion pump (comply with the resistance), e.g. item no.:
1520041600 dewatering pump. For complete vacuum withdra-
wal, if necessary the suction nozzle (Item no.: 1700014701) can be
used in combination with a Vetter aspirator.