VETTER Safety cushion SP 25

Page 7/15

shop area for its next use.

Inspection and cleaning after use

4.4

Re-inflate the soiled safety cushion.
Clean it properly with hand-warm clean or soapy water.
Rinse the soapy water thoroughly and let the safety cushion dry at
normal room temperatures.
The empty compressed-air cylinder needs to be refilled or ex-
changed by a full one.

Important! Check, whether the new compressed-air cylin-
der is tight.

Inspect the safety cushion and the filling gear for possible
damage.

Important Note!

The Safety Cushion

must not

be inflated with a pressure container

having a valve fitted with an integrated excess flow valve (EFV).
In doing this the set-up time would be dangerously extended
thus making it unsuitable for fire service operation. We would like
to point out that the implied valves are not marked and that the
excess flow valve cannot be recognized in the assembled condi-
tion of the valve.
It is for this reason that it is only permitted to inflate with equip-
ment air bottles or inhaling air bottles whose valves

do not have

an integrated excess flow valve.
Empty the safety cushion and close the vent valve.
Fold the safety cushion in accordance with the following packing
plan.
The Vetter safety cushion is now available for its next use.

Storage and maintenance

4.5

Except in rescue and emergency vehicles, the safety cushion
must only be stored in clean and dry conditions as well as in dry
rooms.
Only persons, institutions or firms specifically trained by the ma-
nufacturer and duly authorized are allowed to carry out mainte-
nance work.
If there are any doubts about the reliable functioning or the safety
of the safety cushion ask the manufacturer for a test.

For this purpose return the rescue cushion to the manu-
facturer only without the compressed air cylinder!