Installation Manual 10

Offset vertical enclosures:

If the enclosure depth is 24 inches or more and less than 25 inches (See Art01783):

- Install an angled top baffle [172] between the top rear edge of the refrigerator and

the inside edge of the upper exhaust vent opening.

- Make sure that the angled top baffle is less than 1/4 inch [15] from the top of the

refrigerator.

- Make sure that the angled top baffle is no more than 45° from vertical [20].

- Install an inside corner baffle [173] between the outside edge of the upper exhaust

vent opening and either the side wall of the vehicle or the solid box baffle (depend-
ing on the vehicle design).

If the enclosure depth is 25 inches or more and less than 26 inches (See Art01784):

- Install an angled top baffle [172] between the top rear edge of the refrigerator and

the inside edge of the upper exhaust vent opening.

- Make sure that the angled top baffle is less than 1/4 inch [15] from the top of the

refrigerator.

- Make sure that the angled top baffle is no more than 45° from vertical [20].

- Install an inside corner baffle [173] between the outside edge of the upper exhaust

vent opening and either the side wall of the vehicle or the solid box baffle (depend-
ing on the vehicle design).

- Install a condenser baffle [16] at the lowest edge of the condenser of the refrigera-

tor.

- Make sure that the condenser baffle is 1 inch or less [19] from the condenser.

- Install an absorber baffle [171] 18 inches to 18 1/2 inches above the bottom of the

enclosure [17] (4 1/4 inches to 4 3/4 inches above the top of the lower intake vent
opening) [18] .

- Make sure that the absorber baffle is 1 inch or less [19] from the absorber.

Art01783

15

20

172

172

Art01784

20

15

172

172

10

16

19

18

17

171

19

11