Offset vertical enclosures:
If the enclosure depth is 24 inches or more and less than 25 inches (See Art01783):
- Install an angled top baffle [172] between the top rear edge of the refrigerator and
the inside edge of the upper exhaust vent opening.
- Make sure that the angled top baffle is less than 1/4 inch [15] from the top of the
refrigerator.
- Make sure that the angled top baffle is no more than 45° from vertical [20].
- Install an inside corner baffle [173] between the outside edge of the upper exhaust
vent opening and either the side wall of the vehicle or the solid box baffle (depend-
ing on the vehicle design).
If the enclosure depth is 25 inches or more and less than 26 inches (See Art01784):
- Install an angled top baffle [172] between the top rear edge of the refrigerator and
the inside edge of the upper exhaust vent opening.
- Make sure that the angled top baffle is less than 1/4 inch [15] from the top of the
refrigerator.
- Make sure that the angled top baffle is no more than 45° from vertical [20].
- Install an inside corner baffle [173] between the outside edge of the upper exhaust
vent opening and either the side wall of the vehicle or the solid box baffle (depend-
ing on the vehicle design).
- Install a condenser baffle [16] at the lowest edge of the condenser of the refrigera-
tor.
- Make sure that the condenser baffle is 1 inch or less [19] from the condenser.
- Install an absorber baffle [171] 18 inches to 18 1/2 inches above the bottom of the
enclosure [17] (4 1/4 inches to 4 3/4 inches above the top of the lower intake vent
opening) [18] .
- Make sure that the absorber baffle is 1 inch or less [19] from the absorber.
Art01783
15
20
172
172
Art01784
20
15
172
172
10
16
19
18
17
171
19
11