Cobra Electronics CPI 300 User Manual
Page 7
7
MAINTENANCE & SERVICE
6
TROUBLESHOOTING GUIDE
7
Maintaining Your
Inverter
Your CPI 300 requires very
little maintenance to keep it
operating properly. The exterior
of the unit should be cleaned
periodically with a damp cloth
to prevent accumulation of
dust and dirt. At the same
time, tighten the screws on
the DC input terminals. Keep
vents and fans free from dust
or debris.
Service
You can receive technical
assistance with your unit
through one of our customer
support services:
• Automated Help Desk
is available 24 hours a day,
7 days a week at
773-889-3087.
• Customer Service Operators
are available at
773-889-3087 Monday
through Friday, 8:00 a.m. to
6:00 p.m. CST.
• Questions can be faxed to
773-622-2269.
• Automated Technical
Assistance is available
24 hours, 7 days a week
via e-mail at:
[email protected].
• On-line answers to
frequently asked questions
can be found at:
www.cobra.com
8
Problem/
Possible Solution
Symptom
Causes
Low output voltage
Overload
Reduce the load.
No output voltage
Low input
Recharge battery.
voltage
Check connections
and cable.
Short circuit or
Check AC wiring for short
wiring error
circuit or improper polarity.
No output voltage High input
Make sure the inverter
and ”fault“
voltage
is connected to a
indicator is lit
12 volt battery.
Check regulation of
charging system.
No output voltage
Thermal
Allow inverter to cool down
when load is in
shutdown
Improve ventilation—
excess of 300 watts
make sure ventilation
or 2.6 amperes
openings in the inverter
aren’t obstructed. Lower
ambient temperature.
Low battery
Poor DC wiring,
Use proper cable.
alarm sounds
poor battery
Ensure good connections.
continuously
connection
Use new battery.