Т³гж 8 – Pridiom High Wall Installation Manual User Manual
Page 8
7
INSTALLATION INSTRUCTIONS
5. Piping and wrapping
Bundle the tubing, connecting cable, and
drain hose with tape securely,
evenly as shown in Fig.10.
Because the condensed water from rear
of the indoor unit is gathered in ponding
box and is piped out of room. Do not put
anything else in the box.
Indoor unit
Connective
pipe
Pipe room
Ponding box
Wrapping belt
Connective
cable
Drain hose
Fig.10
Connect the indoor unit first, then the outdoor unit.
Do not allow the piping to let out from the back of the indoor unit.
Be careful not to let the drain hose slack.
Heat insulated both of the auxiliary piping.
Be sure that the drain hose is located at the lowest side of the bundle. Locating
at the upper side can cause drain pan to overflow inside the unit.
Never intercross nor intertwist the power wire with any other wiring.
Run the drain hose sloped downward to drain out the condensed water smoothly.
CAUTION
Install the outdoor unit on a rigid base to prevent increasing noise level and vibration.
Determine the air outlet direction where the discharged air is not blocked.
In the case that the installation place is exposed to strong wind such as a seaside,
make sure the fan operating properly by putting the unit lengthwise along the wall
or using a dust or shield plates.
Specially in windy area, install the unit to prevent the admission of wind.
If need suspending installation, the installation bracket should accord with technique
requirement in the installation bracket diagram. The installation wall should be solid
brick, concrete or the same intensity construction,
or actions to reinforce, damping supporting should
be taken. The connection between bracket and
wall, bracket and the air conditioner should be
firm, stable and reliable.
Be sure there is no obstacle which block
radiating air.
Strong
wind
Fig.11
Outdoor unit installation
Outdoor installation precaution