INSTALLATION INSTRUCTIONS

Indoor unit installation

2. Drill a hole in the wall

Fig.4

Note:

1. Fit the Installation Plate

1. Fit the installation plate horizontally
on structural parts of the wall with
spaces around the installation plate.
2. If the wall is made of brick, concrete or
the like, drill eight (8) 5mm diameter holes
in the wall. Insert Clip anchor for appropriate
mounting screws.
3. Fit the installation plate on the wall with eight
(8) type “A” screws.

Correct orientation
of Installation Plate

Fit the Installation Plate and drill holes in the wall according to the wall structure
and corresponding mounting points on the installation plate.

(Dimensions are in “mm” unless otherwise stated)

1. Determine hole positions according to
the diagram detailed in Fig.5. Drill
one (1) hole (

65mm) slanting slightly

to outdoor side.
2. Always use wall hole conduit when
drilling metal grid, metal plate or the like.

Wall

Indoor

Outdoor

5-7mm

Fig.6

Fig.5

A

40

B

Right rear side

refrigerant

pipe hole

65

Installation plate

Indoor unit outline

Left rear side

refrigerant

pipe hole

65

150mm or more to ceiling

120mm or more

to wall

120mm or more

to wall

A:(<12000Btu/h model:790; >12000Btu/h:920)
B:(<12000Btu/h model:265; >12000Btu/h:293)

90

40

45