GENERAL INFORMATION

GENERAL INFORMATION:

Oldcastle BuildingEnvelope FG-5100 (2-1/2" x 5") impact resistant storefront system represents the

latest in product development technology. This system was especially designed to meet the stringent

requirements of Miami-Dade County and Florida Building Codes as well as the International Building

Code for glass and glazing systems. FG-5100 successfully passed a series of large missile impact and

TM

cyclic wind test with a variety of impact-resistant glass.

BUILDING CODES:

Oldcastle BuildingEnvelope does not control the application nor selection of its product configurations,

sealant or glazing materials and assumes no responsibility thereof. It is the responsibility of the owner,

architect, and installer to make these selections in strict compliance with applicable laws and building codes.

STRUCTURAL SEALANTS:

Dow Corning 995 structural sealants were used on the FG-5100 test specimen for glass to metal

adhesion approved by Miami-Dade County. To comply with Miami-Dade County and Florida Building

Code Protocols, Dow Corning 995 sealant must be used for glass to metal adhesion with FG-5100.

PERIMETER SEALANTS:

Due to varying job conditions, all perimeter sealants used should be approved by the sealant

manufacturer to ensure the sealant will function for the conditions shown on these instructions and shop

drawings. Sealants must be compatible with all surfaces in which adhesion is required, including other

sealants surfaces. Use primers where directed by sealant manufacturer. Be sure to properly store

sealants at recommended temperature and check container for remainder of shelf life before using. Dow

Corning 795 silicone sealant was the perimeter sealant used on the FG-5100 test specimen

approved by Miami-Dade County.

MATERIAL HANDLING:

SHOP

1.

Cardboard wrapped or paper interleaved material must be kept dry.

2. Check arriving materials for quantity and keep record of where various materials are stored.

JOB SITE

1.

Material at job site must be stored in a safe place well removed from possible damage by other

trades.

2. Cardboard wrapped or paper interleaved materials must be kept dry.
3. Keep record of where various materials are stored.
4. Protect materials after erection. Cement, plaster, and other alkaline solutions are very harmful to

the finish.