beautypg.com

Coleman Echelon FC8T User Manual

Page 5

background image

036-21603-002 Rev. A (1004)

Unitary Products Group

5

NOTES

1. Airflow expressed in standard cubic feet per minute (CFM) and in cubic meters per minute (m

3

/min).

2. Return air is through side opposite motor (left side).

3. Motor voltage at 115 V.

* Input / CFM / Cabinet Width (A=14-1/2, B=17-1/2, C=21, D=24-1/2).

TABLE 2: Blower Performance CFM - Upflow (without filter) - Left Side Return

MODELS

Input /

CFM

Speed

Two Stage Left Side Airflow Data (SCFM)

Ext. Static Pressure (in. H2O)

0.1 0.2 0.3 0.4 0.5 0.6 0.7 0.8 0.9 1.0

(F,L)C8T060A12UH11

High

1770 1690 1630 1560 1490 1390 1290 1190 1050 920

Medium

High 1400 1380 1350 1320 1280 1230 1160 1060 930 780

Medium

Low 1120 1130 1150 1130 1120 1080 1000 950 790 630

Low

880 900 900 900 880 850 790 730 660 530

(F,L)C8T080A12UH11

High

1790 1720 1670 1590 1530 1450 1350 1260 1140 1000

Medium

High 1420 1370 1350 1320 1280 1230 1170 1090 990 840

Medium

Low 1080 1120 1110 1100 1080 1040 1000 920 820 690

(F,L)C8T080B16UH11

Low

N/A 900 900 890 870 850 800 730 670 560

High

2000 1960 1930 1900 1800 1760 1710 1640 1550 1460

Medium

1440 1440 1430 1420 1400 1380 1340 1300 1220 1150

Low

1220 1230 1230 1230 1200 1190 1170 1160 1110 1050

FC8T100B12UH11

High

1780 1710 1640 1560 1490 1390 1290 1180 1030 820

Medium

High 1430 1410 1370 1340 1280 1220 1140 1040 890 730

Medium

Low 1140 1170 1150 1120 1080 1040 970 890 760 630

Low

920 940 950 940 920 890 850 770 660 560

(F,L)C8T100C20UH11

High

2770 2670 2610 2540 2450 2340 2210 2070 1890 1730

Medium

High 2120 2060 2030 2000 1950 1880 1810 1720 1580 1370

Medium

Low 1690 1660 1630 1610 1560 1490 1420 1350 1240 1070

Low

1390 1370 1330 1290 1250 1200 1120 1010 910 850

FC8T120C16UH11

High

2160 2070 1990 1900 1800 1690 1580 1430 1260 1000

Medium

1760 1720 1690 1630 1560 1480 1390 1250 1080 890

Low

1510 1490 1470 1440 1380 1300 1210 1110 950 780

FC8T120C16UH11

High

2740 2650 2560 2480 2380 2280 2170 1990 1840 1650

Medium

High 2120 2090 2040 2000 1940 1870 1780 1680 1550 1370

Medium

Low 1690 1670 1650 1610 1560 1510 1440 1310 1160 1030

Low

1390 1360 1330 1300 1250 1190 1100 1020 940 840

Field Wiring for Single Stage Thermostat

BLK

WHT

GRN

BLK (HOT)

WHT (NEUTRAL)

GRN

NOMINAL
120 VOLT

Y

W1

R

G

C

Y1

Y2

Y

W1

W

W2

R

G

C

SINGLE STAGE
THERMOSTAT

T’STAT
COMMON
CONNECTION

Field Wiring for Two Stage Thermostat

Y1

Y2

W1

W2

R

G

C

X/L

Y1

Y2

R

C

X/L

INTEGRATED
CONTROL

T’STAT
COMMON
CONNECTION

TWO-STAGE
THERMOSTAT

OUTDOOR
UNIT