Annual Fuel Utilization Efficiency (AFUE) numbers are determined in accordance with DOE Test procedures.
Wire size and over current protection must comply with the National Electrical Code (NFPA-70-latest edition) and all local codes.
The furnace shall be installed so that the electrical components are protected from water.

* ESP (External Static Pressure) .5" WG is at furnace outlet ahead of cooling coil.

NOTES:

1. All filters must be high velocity cleanable type.
2. Air flows above 1800 CFM require either return from two sides or one side plus bottom.

RATINGS & PHYSICAL / ELECTRICAL DATA

Model

Output

Nominal

Cabinet

Width

AFUE

Air Temp. Rise

Max. Outlet

Air Temp.

MBH

CFM

In.

°F

°F

(F,L)C8T060A12UH11

46/34

1200

14-1/2

80.0

25-55

165

(F,L)C8T080A12UH11

64/48

1200

14-1/2

80.0

30-60

175

(F,L)C8T080B16UH11

64/48

1600

17 1/2

80.0

25-55

160

FC8T100B12UH11

80/53

1200

17 1/2

80.0

25-55

170

(F,L)C8T100C20UH11

80/53

2000

21 80.0

25-55

160

FC8T120C16UH11

96/64

1600

21 80.0

25-55

180

(F,L)C8T120C20UH11

96/64

2000

21 80.0

25-55

170

Model

Output

Blower

Blower

Size

Total

Unit

Max Over-current

Size (awg) @

75 ft.protect

Min.

Wire

one way

Operation

WGT.

MBH

Hp

Amps

In.

Amps

LBS

(F,L)C8T060A12UH11

46/34

1/3

6.2

10 x 7

9.0

20

14

107

(F,L)C8T080A12UH11

64/48

1/3

6.2

10 x 7

9.0

20

14

119

(F,L)C8T080B16UH11

64/48

3/4

11.5

11 x 8

12.0

20

14

129

FC8T100B12UH11

80/53

1/2

7.0

10 x 8

12.0

20

14

131

(F,L)C8T100C20UH11

80/53

1.0

12.2

11 x 10

14.0

20

12

149

FC8T120C16UH11

96/64

1/2

10.4

10 x 10

12.0

20

14

149

(F,L)C8T120C20UH11

96/64

1.0

12.2

11 x 10

14.0

20

12

151

FILTER SIZES

Cabinet Size

Side (in)

Bottom (in)

A

16 x 26

14 x 26

B

16 x 26

16 x 26

C

(2) 16 x 26

20 x 26

D

(2) 16 x 26

20 x 26