Craftsman 81079 User Manual
Page 9

9
Diode Test
Test current of 0.3mA maximum,
open circuit voltage 1.5V DC typical
Continuity Check
Audible signal will sound if the
resistance is less than 150!
(approx.), test current <0.7mA
Temperature Sensor
Requires type K thermocouple
IR Spectral response
6 to 16!m
IR Emissivity
0.95 fixed
IR distance ratio
8:1
Input Impedance
>7.5M" (VDC & VAC)
AC Response
True rms
ACV Bandwidth
50Hz to 1kHz
Display
4000 count backlit liquid crystal
Overrange indication
“OL” is displayed
Auto Power Off
15 minutes (approximately)
Polarity
Automatic (no indication for
positive); Minus (-) sign for negative .
Measurement Rate
2 times per second, nominal
Low Battery Indication
“ ” is displayed if battery voltage
drops below operating voltage
Battery
one 9 volt (NEDA 1604) battery
Fuses
mA, !A ranges; 0.5A/250V fast blow
A range; 20A/250V ceramic fast
blow
Operating Temperature
32
o
F to 122
o
F (0
o
C to 50
o
C)
Storage Temperature
-4
o
F to 140
o
F (-20
o
C to 60
o
C)
Relative Humidity
<70% operating, <80% storage
Operating Altitude
7000ft. (2000) meters maximum.
Weight
0.753lb (342g) (includes holster).
Size
7.36” x 3.2” x 2.0” (187 x 81 x
50mm) (includes holster)
Safety
For indoor use and in accordance
with the requirements for double
insulation to IEC1010-1 (1995):
EN61010-1 (1995) Overvoltage
Category III, Pollution Degree 2.