beautypg.com

3 installation, 4 electrical specifications – Kontron CP3-SVE-M76AC User Manual

Page 7

background image

RID 24139 PD13, Rev. 01

Page 7

CPCI Power Supply

PD13: CP3-SVE-M76AC

2.3

Installation

Thanks to its plug-in compatibility this DIN M-type power supply unit allows for an easy instal-
lation, by which the power supply unit’s male DIN M24/8 power connector is inserted into the
backplane’s mating female connector without the need of any intermediate adaptation.

2.4

Electrical Specifications

Input

Output

Regulation

Input voltage ranges

115/230 VAC, 50/60 Hz, automatic switching
ranges: 90 … 138 VAC or 184 ... 264 VAC

Efficiency

> 80 % (typical)

Inrush current limitation

25 A

peak

cold

35 A

peak

warm

Fuse

3.15 AT (internal, not user serviceable)

Hold-up time

115 V: > 30 ms at 100 % load
230 V: > 35 ms at 100 % load

Output power V

1

(5.1 V)

voltage: 5.1 V, +5/-3% (including ripple and noise)
current: min 0.0 A; nominal 8.0 A; peak 12 A for 100 ms

Output power V

2

(3.3 V)

voltage: 3.3 V, +5/-3% (including ripple and noise)
current: min 0.0 A; nominal 8.0 A; peak 12 A for 100 ms

Output power V

3

(12 V)

voltage: 12 V, +8/-7% (including ripple and noise)
current: min 0.0 A; nominal 0.15 A; peak 0.2 A

Ripple

V

1

, V

2

: < 50 mV

pp

V

3

: < 200 mV

pp

Total output loads

min 0 W; max 75 W for all outputs

Status indication

green LEDs for V

1

, V

2

Rise-delay time

< 1 s at 115/230 VAC

Start-up time

≤ 15 ms

Line regulation

< 0.2 % for V

1

, V

2

at a load of 8.0 A each

Load regulation

< 0.5 % for V

1

, V

2