PD05: CP3-SVE-P200AC
CPCI Power Supply
Page 10
© 2002 PEP Modular Computers GmbH
RID 24139 PD05, Rev. 01
ENVIRONMENTAL
Conducted
Disturbance
Per EN61000-4-6, level 2.
3
V
Insulation
Resistance
Input to Output.
10
M
Ω
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX
UNITS
Altitude
Operating.
Non-Operating.
10k
40k
ASL Ft.
Operating
Temperature
With 250 LFM forced-air cooling At 100% load:
Derate linearly above 50°C by 2.5% per °C. At 50%
load:
0
50
70
°C
Storage
Temperature
- 40
+ 85
°C
Relative Humidity
Non-Condensing.
5
95
%RH
Shock
Peak acceleration.
20
GPK
Vibration
Random vibration, 10 Hz to 2 kHz, 3 axis.
6
GRMS
Warning!
A d e q u a t e t h e r m a l c o o l i n g o f t h e p o w e r s u p p l y m u s t b e e n s u r e d .
Therefore do not obstruct or hinder cooling air circulation or heat con-
duction within the power supply or surrounding equipment.
Fa ilure to comply wit h t his warn ing ma y re sult i n da mage to yo ur
equipment.
SAFTEY, REGULATORY, AND EMI
PARAMETER
CONDITIONS/DESCRIPTION
MIN
NOM
MAX