beautypg.com

3 auxiliary connectors and signals, 4 system management connectors jp19 and jp20 – Kontron CP6-BP8-P47-STD User Manual

Page 10

background image

PD11: CP6-BP8-P47-STD

CPCI Backplane

Page 10

© 2002 PEP Modular Computers GmbH

RID 24229 PD11, Rev. 01

5.3

Auxiliary Connectors and Signals

There are two, two-contact, male auxiliary connectors, JP16 and JP17, available on this back-
plane.

JP16 and JP17 make the signal lines, PRST and INH# respectively, available for external
switches to either invoke a system reset or to switch the power supply on or off.

Figure 5:

Orientation and Pinouts of CP6-BP8-P47-STD Connectors JP16 and JP17

5.4

System Management Connectors JP19 and JP20

Two five-contact male system management bus (IPMB0/1) connectors, JP19/20, are provided
for external interfacing to this bus.

Figure 6: Orientation and Pinout of the CP6-BP8-P47-STD IMPB0/1 Connectors JP19/20

1

2

JP17 JP16

Table 6: Pinouts of CP6-BP8-P47-STD
Connectors JP16 and JP17

Pin

Function

JP16

1

GND

2

PRST

JP17

1

GND

2

INH#

1

5

Table 7: Pinout of CP6-BP8-P47-
STD IMPB0/1 Connectors JP19/20

Pin

Function

1

IMPB0_SCL / IMPB1_SCL

2

GND

3

IMPB0_SDA / IMPB1_SDA

4

IMPB_PWR / V

5

SMB_Alert *

* JP20 only