3 auxiliary connectors and signals, 4 system management connectors jp19 and jp20 – Kontron CP6-BP8-P47-STD User Manual
Page 10
PD11: CP6-BP8-P47-STD
CPCI Backplane
Page 10
© 2002 PEP Modular Computers GmbH
RID 24229 PD11, Rev. 01
5.3
Auxiliary Connectors and Signals
There are two, two-contact, male auxiliary connectors, JP16 and JP17, available on this back-
plane.
JP16 and JP17 make the signal lines, PRST and INH# respectively, available for external
switches to either invoke a system reset or to switch the power supply on or off.
Figure 5:
Orientation and Pinouts of CP6-BP8-P47-STD Connectors JP16 and JP17
5.4
System Management Connectors JP19 and JP20
Two five-contact male system management bus (IPMB0/1) connectors, JP19/20, are provided
for external interfacing to this bus.
Figure 6: Orientation and Pinout of the CP6-BP8-P47-STD IMPB0/1 Connectors JP19/20
1
2
JP17 JP16
Table 6: Pinouts of CP6-BP8-P47-STD
Connectors JP16 and JP17
Pin
Function
JP16
1
GND
2
PRST
JP17
1
GND
2
INH#
1
5
Table 7: Pinout of CP6-BP8-P47-
STD IMPB0/1 Connectors JP19/20
Pin
Function
1
IMPB0_SCL / IMPB1_SCL
2
GND
3
IMPB0_SDA / IMPB1_SDA
4
IMPB_PWR / V
5
SMB_Alert *
* JP20 only