beautypg.com

Kontron CRMS Rack Mount Kits User Manual

Page 5

background image



5

Sep-09

www.kontron.com

TMLPMOUNT41, TMLPMOUNT51 and TMLPMOUNT52

TMLPMOUNT41/51/52 series mounts Communication Rack Mount Servers to 2-post or 4-post
racks.

TMLPMOUNT41 and TMLPMOUNT51 are used for mounting servers on 19-inch wide racks.
These racks are considered standard EIA (universal hole spacing) racks.

TMLPMOUNT52 is used for mounting servers on 23-inch wide racks. These racks could be
standard EIA (universal or wide hole spacing) or ETSI (European) racks.

TMLPMOUNT41/51/52 series are designed with a slide-in rail-type system. Although the
mounts are designed as rails, they are not sliding rails. This means the servers can be slid into
the racks for installation purpose, but the rails are not designed to support a mounted server
during service.

TMLPMOUNT4x/5x Feature Comparison

S

li

d

e

p

u

ll

-o

u

t

lo

c

k

in

g

f

e

a

tu

re

S

li

d

e

i

n

te

rf

a

c

e

m

a

te

ri

a

l

4

-p

o

s

t

ra

c

k

h

o

le

s

p

a

c

in

g

2

U

-t

a

ll

n

u

t

b

a

r

2

-p

o

s

t

c

h

a

s

s

is

s

e

c

u

ri

n

g

s

c

re

w

lo

c

a

ti

o

n

"H

P

M

u

la

n

ra

c

k

i

n

te

rf

e

re

n

c

e

"

TMLPMOUNT41

No

1

Plastic

strips

2

EIA-Universal

Not included

Side

access

6

Interference

TMLPMOUNT51

Yes

Xylan

coating

3

EIA-Wide or EIA-

Universal

4

Included

5

Front

access

No Interference

TMLPMOUNT52

Yes

Xylan

coating

3

EIA-Wide, EIA-

Universal or ETSI

Included

5

Front

access

N/A

Notes:

1. Extra care must be exercised with TMLPMOUNT41 to securely hold the server with one's hands

when sliding it out of the rack; otherwise, the server could fall to the ground as it is being removed.

2. Plastic strips on TMLPMOUNT41 have peeled off in some customer installations. The result of this is

that the parts are usable, but the server could have somewhat of a "scrape-in feel" rather than "slide
in". Also, the rails will fit sloppier, so the side-located chassis securing screws could be difficult to
align in 2-post installations. Replacement material is available from the plastic strip manufacturer.

3. Xylan is a tough, low-friction coating similar to Teflon.
4. EIA-Wide spacing doesn't have the interstitial hole that is present in EIA-Universal. TMLPMOUNT51

contains an adapter bracket to overcome this EIA-Wide issue.

5. This component (2U Nut Bar) enables installation of a rail kit into a 1U rack slot when there is already

equipment installed both above and below that open slot.

6. The sides of the server must be accessible when using TMLPMOUNT41 in 2-post racks.