Standards for the CP3002-RA
The CP3002-RA complies with the requirements of the following standards:
Table 1-3:
Standards for the CP3002-RA
TYPE
ASPECT
STANDARD
REMARKS
CE
Emission
EN55022
EN61000-6-3
--
Immission
EN55024
EN61000-6-2
--
Electrical Safety
EN60950-1
--
Mechanical
Mechanical Dimensions
IEEE 1101.10
--
Environmental
Climatic Humidity
IEC60068-2-78
See note below
WEEE
Directive 2002/96/EC
Waste electrical and electronic equipment
RoHS
Directive 2002/95/EC
Restriction of the use of certain hazardous
substances in electrical and electronic
equipment
Vibration
(Sinusoidal)
IEC60068-2-6
TBD
Single Shock
IEC60068-2-27
TBD
Permanent Shock
IEC60068-2-29
TBD
Note ...
Kontron performs comprehensive environmental testing of its products in accor-
dance with applicable standards.
Customers desiring to perform further environmental testing of Kontron prod-
ucts must contact Kontron for assistance prior to performing any such testing.
This is necessary, as it is possible that environmental testing can be destructive
when not performed in accordance with the applicable specifications.
In particular, for example, boards without conformal coating must not be
exposed to a change of temperature exceeding 1K/minute, averaged over a
period of not more than five minutes. Otherwise, condensation may cause irre-
versible damage, especially when the board is powered up again.
Kontron does not accept any responsibility for damage to products resulting
from destructive environmental testing.