97refrigerantaccessvalvesinstructions2.ai, Refrigerant access valves and hose connectors – Just Better 720-97 ARI Standard Refrigerant Access Valves and Hose Connectors User Manual
Page 2

2
Refrigerant Access Valves and Hose Connectors
DIA.
REF.
2
2
DIA.
MIN. DIA.
EXACT
DATUM DIA.
.1693
.210-36UNS-1MOD.P.D. TH'D.
.189
.181
.192
.197
.4091
.3941
MIN.FULL
TH'D DEPTH
.293
3
1
1
17°±30'
INCL. ANGLE
.168
.155
.150
.551
1
2
3
Counterbore and/or Chamfer Optional.
This Diameter Must Be Concentric With Pitch
Diameter Of Internal Th'd. Within .003 T.I.R.
1/4" SAE Flare External Dimensions To
Conform To ANSI/SAE J513f "Refrigeration
Tube Fittings"
Figure 2
TYPICAL BODY DIMENSIONS
CONVERSION TABLES
INCHES
MILIMETERS
.875
22.2
.551
14.0
.4091
10.39
.3941
10.01
.308
7.82
.293
7.44
.189
4.80
.181
4.60
.1719
4.366
.1693
4.300
.168
4.27
.155
3.94
.150
3.81
.109
2.77
.076
1.93
.064
1.63
.035
0.89
.025
0.64
.010
0.25
.003
0.08
DEGREES
RADIANS
17°30'
0.3054
16°30'
0.2880
IN.LBS.
CM.KG.
1-1/2
1.7
3
3.5
.1719 DIA.
BALL
EXACT
DATUM DIA.
.1693
.4091
.3941
.308
.293
ANSI/ARI Standard 720-97 used by permission
Figure 3
TYPICAL CORE DIMENSIONS
Figure 4
PLUG GAGE
VALVE
SEAL
REF.
CORE
SEAL
.025
.076
.064
DIA.
.206-36 UNS-1
MOD. TH'D.
REF.
.109
4
.875
MAX.
4
Sealing Materials to Be Compatible
with Halogenated Hydrocarbon
Refrigerants and Refrigerant Oil For
The Intended Application.
Section 5. Dimensions and Materials
Figure 5
BALL GAGE
ACCESS VALVE BODY GAGING PROCEDURES
Dimensions In Inches
5.1Dimensions . See Figures 2 and 3 (above).
5.1.1 While conformance to Figures 2 and 3 is
recommended, where components do not meet the
constructional and dimensional requirements
shown, all access valves shall still interchange with
components that meet these requirements and
shall comply with all mandatory requirements to be
in conformance with this standard.
5.2Materials. Materials used for the seals on the valve
core shall be compatible for service with halogenated
hydrocarbon refrigerants and refrigerant oil for the
intended application.
Section 6. Gaging Procedures
6.1
Gaging. Figures 4 and 5 (above) show two
accepted methods of gaging the access valve body.
Section 7. Voluntary Conformance
7.1
Conformance. While conformance with this
standard is voluntary, conformance shall not be
claimed or implied for products or equipment within its
Purpose (Section 1) or Scope (Section 2) unless such
claims meet all of the requirements of the standard.
APPENDIX A. References-Normative
A1
Listed here are all standards, handbooks, and other
publications essential to the formation and
implementation of the standard. All references in this
appendix are considered as part of the standard.
A1.1 ANSI/SAE Standard J513f-MAY94,
Refrigeration Tube Fittings , 1994, American
National Standards Institute/Society of Automotive
Engineers, 11 West 42nd Street, New York, NY
10036, U.S.A./400 Commonwealth Drive,
Warrendale, PA 15096, U.S.A.
A1.2 ASHRAE Terminology of Heating, Ventilation,
Air Conditioning and Refrigeration, American
Society of Heating, Refrigerating and Air-
Conditioning Engineers, Inc., 1791 Tullie Circle
N.E., Atlanta, GA 30329, U.S.A.
APPENDIX B. References-Informative
A1
None.
REFRIGERANT ACCESS VALVE DIMENSIONS
1/4" SAE FLARE SIZE
Dimensions In Inches
4301 N. Fairfax Drive, Suite 425, Arlington, VA 22203
Phone: 703-524-8800 Web: www.ari.org
ARI Standard 720-97
TM
JB INDUSTRIES
630.851.9444
Printed in USA
© 2007 J/B Industries Inc.
www.jbind.com
[email protected]