1.
Get the appliance ready for use. Close the lid tightly. The lid
must audibly engage at each sides of the appliance.
2.
Take the provided vacuum hose and connect the narrow adap-
ter plug to the vacuum port at the right side of the appliance
(see picture J). The adapter plug must be attached securely
and should not be able to slip off.
3.
Fill the container with its contents.
noTe: Do not overfill the container. When vacuum sealing food
in a container leave 3 cm of free space underneath the lid of
the container.
4.
Place the wide adapter of the vacuum hose over the black rub-
ber seal on the lid of the container. Press the adapter slightly
down. The connection must be sealed tightly (picture J).
noTe: Ensure that the adapter lies correctly in the recess of the
container and is flush with the surface of the lid.
5.
Press the Vacuum Seal button (picture K). The vacuum pump starts to operate audibly.
The vacuum pump indicator illuminates in green. The appliance is generating a vacuum.
After some seconds, the sealing indicator illuminates in red. As soon as the vacuum pro-
cedure is finished, both indicators switch off. The food is now vacuum-packed.
6.
Remove the vacuum hose from the container. If you wish to vacuum seal another contai-
ner, wait approximately 2 minutes to let the appliance cool down. Thereafter, repeat the
process.
TiP: If you wish to open the container, push the rubber seal outwards until you hear a his-
sing sound of air. Hold the seal for 2-3 seconds and then open the lid.
7.
When you have finished vacuum sealing, just pull the small adapter of the vacuum hose
upwards to remove it from the vacuum port.
solVing ProBlems
If any problems occur during operation, you will find solutions in the following table.
Problem
The easy solution
The appliance does not operate
when trying to start it
• Check, whether the appliance is properly connected
to a power outlet and check if the power outlet does
work. Therefore connect another appliance to the
same power outlet.
• Check, whether the power cord and the plug are
defective. Contact an authorised service centre, if they
are defective.
• The appliance shuts off automatically to prevent
overheating. Let the appliance cool down for 20
minutes and try again.
The appliance does not seal the
bag
• Check whether the bag is in proper position (see:
‘Sealing the Plastic Bag’), and check, whether the bag
is clean and dry in the sealing section and lies evenly.
Problem
The easy solution
The appliance does not gene
rate a full vacuum
• Check, whether:
- the bag is in proper position (see: ›Sealing the
Plastic Bag‹) and whether the end of the bag
extends into the vacuum chamber.
- the gaskets are clean and in perfect condition.
- little pieces of food are inside the plastic bag
on the section of the sealing band.
- the bag is leaking. You can proof this by
dipping the sealed bag into water. In case of
leaking, air would escape when you put slight
pressure on the bag. Seal the bag again or use
a new one.
The appliance does not seal the
plastic bag properly
• Check, whether:
- the bag is in proper position (see: ›Sealing the
Plastic Bag‹) and whether the end of the bag
extends into the vacuum chamber.
- something sticks to the sealing band or gaskets.
- little pieces of food are inside the plastic bag
on the section of the sealing band.
• In case of an overheated sealing band the bag
would melt. Open the appliance and let it cool
down for a few minutes.
• In the event of overheating the appliance will
automatically shut down (thermal cut out) to pre-
vent damage. Let the appliance cool down for 20
minutes and try again.
The appliance does not
generate a vacuum inside
the container
• Check, whether:
- the vacuum hose is connected properly to the
vacuum port and container (see: ›How to Vacu-
um Seal a Container‹).
- the lid of the container is closed properly and
the black rubber seal on the lid of the contai-
ner is properly attached to the lid.
- the black rubber seal of the vacuum chamber is
porous and/or leaking.
- the vacuum hose is defective.
- the container is overfilled. Leave 3 cm of free
space underneath the lid!
picture J