3 causes and rectification of faults – CASO Germany MCDG 25 master User Manual
Page 65
caso MCDG 25 Master (black)
65
Error code Description
E01
Excessive temperature within cooking chamber
The overheating cut-out terminated the current program at a cooking
chamber temperature of 250 °C.
Press the Stop button to acknowledge this fault.
The device can be re-activated after the cool down phase.
E02
Low temperature protection
When the system enters into super low temperature protection status, the digital
display shows “E02” and continues to beep till the system comes back to normal
condition and then press “Stop”.
E03
Sensor fault
The device has detected an error on a sensor and has terminated the
current programme.
Press the Stop button to acknowledge this fault.
Please note
► If error messages continue to appear after an extended waiting period and restarting
the device, then the device will need to be sent to Customer Service to be inspected.
15.3 Causes and rectification of faults
The following table assists in localizing and rectifying minor faults.
Error
Possible cause
Action
The selected program will
not start.
Device door is not closed
Close device door
Power plug is not
plugged in
Plug in mains plug!
Fuse is not activated
Activate fuse
The turntable turns jerkily.
Dirt between the turntable
and the base of cooking
camber
Remove dirt
Dirt on rolling ring
Cooking vessel too large
Use different cooking vessel
Food is not sufficiently
defrosted, warmed up or
cooked after preset time
has elapsed.
Incorrectly selected time
or power level
Re-set time and power level
Repeat process
The device functions but
the cooking chamber
lighting does not work.
Defective cooking
chamber light.
Have Service dept repair
cooking chamber light.