8 the meaning of displayed symbols, The meaning of displayed symbols – Salter Brecknell LPS-15 User Manual
Page 18

16
LPS Series User Instructions
3.8 The Meaning of Displayed Symbols
xxxxxx kg/lb
the scale capacity is xxxxxx kg/lb
0----
zero point is over calibration zero + 10% Full capacity
0-----
zero is below calibration zero - 10%Full capacity
Ad---
ADC is over max. range
Ad _ _ _
ADC is below min. range
-----
weight signal is too large
_ _ _ _ _
weight signal is too small
EEP.E0
the EEPROM can't be accessed
EEP.E1
The parameters are not same with backup data
EEP.E2
The setting parameter(s) is not in normal range
A.oFF.x
the auto-off time is set to x minutes,(when x=0,the scale will not auto-shutoff
CAL-Px
scale's calibration point
CAL.Er
- there is an error in calibration
display division is xxxxx, (xxxxx=500…80000)
selected the unit for the capacity and standard calibration weight is kg(x=0, uu=kg), or
lb( x=1, uu=lb).
d. x
division size is x, (x=1,2,5)
dot. x
the location of decimal point,(x=0,1,2,3)
hold function is active.
F-Set
in Function Set mode
FS---
selected Full Scale of the scale is larger than 5 1/2 LCD display capacity (199999)
FS. oN(oFF)
Full Scale selection enable (disable)
tr. oN(oFF)
tracking enable(disable)
Hab / L cdef
alternately display these information, that means: the display weight is 'abcdef' kg/lb, this
only occurs when current weight is larger than 199999kg/lb (not include decimal point).