ELECTRICAL (Continued)
3. Disconnect pK>wer before servicing motor or pump. If the
disconnect switch is out of sight of pump, lock it open
and tag it to prevent unexpected power application.
4. Ground the pump permanently using a wire of the same
size as that specified in wiring chart (below). Make
ground conneetion to green grounding terminal under
motor canopy marked GRD. or ©.
5. Connect ground wire to a grounded lead in the service
panel or to a metal underground water pipe or well cas
ing at least 10 feet long. Do not connect to plastic pipe or
insulated fittings.
6. Protect current carrying and groimding conductors from
cuts, grease, heat, oil, and chemicals.
7. Connect current carrying conductors to terminals LI and
L2 under motor canopy. When replacing motor, check
wiring diagram on motor nameplate against Figure 6. If the
motor wiring diagram does not match the diagrams in
Figure 6, follow the diagram on the motor.
IMPORTANT: 115/230 Volt single phase models are
shipped from factory with motor wired for 230 volts. If
power supply is 115 volts, remove motor canopy and re
connect motor as shown in Figure 6. Do not try to run motor
as received on 115 volt current.
8. Motor has automatic internal thermal overload protec
tion. If motor has stopped for unknown reasons, thermal
overload may restart it unexpectedly, which could cause
injury or property damage. Disconnect power before ser
vicing motor.
9. If this procedure or the wiring diagrams are confusing,
consult a licensed electrician.
WIRING CHART
Recommended Wire and Fuse Sizes
DiSTANCE iN FEET FROM MOTOR TO METER
Branch
0’
51’
101’
201’
301’
401’
Max.
Fuse*
Min.
TO
TO
TO
TO
TO
TO
Pump
Load
Rating*
Wire
50’
100’
200’
300’
400’
500’
Model
HP
Volt
Amps
Amps
Size
WiRE SiZE
390.262454
1
115
14.2
20
12
12
12
8
6
6
4
230
7.6
15
14
14
14
14
14
12
10
390.262553
1-1/2
115
19.2
25
10
10
10
8
6
4
4
230
9.6
15
14
14
14
14
12
10
10
390.262653
2
230
12.0
15
14
14
14
14
12
10
10
*Dua! element or Fusetron time delay fuses recommended for all motor circuits.