SERVICE AND ADJUSTMENTS
HOW TO REMOVE AN OBJECT
FROM THE AIR INTAKE
WARNING:
Stop the unit and
disconnect from the power source be
fore opening the inlet cover. The mo
tor must be stopped and the impeller
blades no longer turning to avoid seri
ous injury from the rotating blades.
1. While holding the inlet cover open,
remove the vacuum tubes. The in
let cover must be held open through
all remaining steps.
2. Carefully reach into the vacuum
opening and clear out the air intake
area. Clear all debris from impeller.
3. Inspect the impeller for cracks. If
cracked or damaged, do not use the
unit. Have parts replaced by your
Sears Service Center. Do not at
tempt to replace them yourself.
PARTS AVAILABLE
Blower Tube/Nozzle ... 530403612
Vacuum Tube Set ............ 530402499
Inlet Restrictor.................. 530402045
Collection Bag .................. 530402533
Gutter Kit................................ 71-79997
Safety Glasses....................... 71-85707
Extension Cord...................... 71-5702
STORAGE
^ WARNING:
Perform the follow
ing steps after each use:
• Stop unit and disconnect from the
power source.
• Store the unit in a stable location. Se
cure the unit before transporting.
• Store unit with all guards in place.
Position unit so that any sharp object
cannot accidentally cause injury.
• Store unit well out of the reach of chil
dren.
Prepare unit for storage at the end of
the season or if it will not be used for
30 days or more.
BLOWER STORAGE
• Disconnect from the power source.
Clean the entire unit.
Open inlet cover and clean any dirt,
grass, or debris that has collected. In
spect the blower and all tubes. Close
and make sure the cover is latched.
Clean air vents and air inlet of debris.
Store your unit and extension cord in a
well ventilated area and covered, if
possible, to prevent dust and dirt accu
mulation. Do not cover with plastic.
Plastic cannot breathe and may cause
condensation and eventual rust or cor
rosion.
Check entire unit for loose screws,
nuts, and bolts. Replace any dam
aged, worn, or broken parts.
TROUBLESHOOTING TABLE
^WARNING: Always stop unit and disconnect from the power source before
performing al! of the recommended remedies below except remedies that re
quire operation of the unit.
SYMPTOM
CAUSE
REMEDY
Unit fails to
operate.
1. Switch in the OFF position.
2. Extension cord disconnected.
3. Circuit breaker tripped, or
fuse blown.
4. Mechanical failure
1. Slide switch to ON position.
2. Reconnect extension cord.
3. Reset circuit breaker or
fuse.
4. Contact your Sears Service
Center.
Unit
vibrates
abnormally.
1. Mechanical failure
1. Contact your Sears Service
Center.
Impeller will
not turn
freely.
1. Debris in air intake area.
2. Mechanical failure.
1. Clean unit. Remove any
debris.
2. Contact your Sears Service
Center.