C. With finger pressure press seat firmly and squarely into cav
ity. See Figure lOA. Polished face of seat faces inside of pump.
If seat wUI not locate properly, plgpe cardboard washer over
polished face and use piece of 3/4” standard pipe for press
ing purposes. See Figure’ lOB.
FIGURE lOA
477
0194
FIGURE I OB
483
0194
J. Reposition capacitor and replace motor canopy.
K. Remount diffuser on seal plate.
Cleaning Impeller
1. Follow steps lA through IE under “Disassembly and Assembly
of Pump" on Page 7.
2. Remove dififuser and impeller from pump per instructions under
“Removing Motor for Service and Replacing Shaft Seal” on Page
7.
3. Clean impeller and reassemble impeller and diffuser per in
structions under “Removing Motor for Service and Replacing
Shaft Seal” on pages 7 and 8.
Cleaning Shallow Well Jet
To remove debris from venturi or nozzle, proceed as follows:
1. Disassemble pump per instructions on Page 7.
2. Turn venturi counterclockwise and remove it. The nozzle is
now exposed. Remove it using a 5/8” hex socket wrench witli
extension. Turn counterclockwise. If socket wrench is not avail
able, insert an ice pick or similar pointed tool carefully into the
nozzle. This will dislodge debris.
3. Flush out tlie debris by running water through the nozzle in the
same direction as the dislodging tool was inserted.
4. Reinstall nozzle and venturi. Do not overtighten!
5. Reassemble pump per instructions on Page 7.
HELPFUL HINTS
How to Handle a Gaseous Well
In some areas well water contains gases which must be allowed to
escape before the water is used. This can be done as shown in
Figure 12.
D. Dispose of cardboard washer and clean surface of seat.
E. Clean motor shaft.
F. Reassemble back half of pump to motor.
G. Apply detergent solution to inside diameter of rotating seal
member.
H. Slide rotating member on shaft until rubber drive ring hits
shaft shoulder. NOTICE: BE SURE you do not chip or scratch
seal face on shaft shoulder or seal will leak!
I. Screw impeller on shaft (clockwise) while holding shaft with
7/16” open end wrench on shaft flats. This will automatically
locate seal in place. Sec Figure 11.
FIGURE 11
Gàses -
/ÌS6 !□
surface
Pipe strap or-
wire to hold
pipe sleeve
vm
Not
to
Scale
Tail —
pipe
Fool-'
valve
Pipe —
sleeve
Pipe
cap
Figure 12
A good way of delivering gas-free water is to suspend a pipe, closed
at the bottom and open at the top, surrounding the suction pipe.
Since the gases rise in the well casing, the water sucked down
through the pi pe and into the suction pipe is free of gas. This type
of well must be vented to the outside of any enclosure.
Air Control In Flowing Wells
Flowing wells, or wells with litde or no drawdown, could create a
special problem in air control in the operation of your water sys
tem.
In such cases, install a Captive Air® Tank. It does not require any