BEFORE EACH USE

• Check water inlet screen for damage.

• Check high pressure hose for leaks.

• Check chemical tanks and filters for damage.

• Check gun and wand assembly for leaks.

• Purge pump of air and contaminants.
■ Check engine oil level.

PRESSURE WASHER MAINTENANCE

Check and Clean Inlet Screen

Examine garden hose inlet screen. Clean if it is,

clogged or replace if it is tom.

Check High Pressure Hose

High pressure hose can develop leaks from wear,
kinking, or abuse. Inspect hose each time before using
it. Check for cuts, leaks, abrasions, bulging of cover,
or damage or movement of couplings. If any of these

conditions exist, replace hose imrhediately.

A

DANGER: Never repair a high pressure hose.
Replace with hose with one that meets the
minimum pressure rating of the system.

Check Ch^ical Reservoirs

Tank covers should snap cleanly onto tank. Ensure
chemical labels correctly identify tank contents.

Ensure that the System Rinse tank is filled with clean

water. Ensure that Dial-A-Cleaner™ selector knob

rotates freely between each position. Examine the

tanks and replace if the filter is clogged

Check Gun and Wand

Examine hose connection to gun and make sure it is

secure. Test trigger by pressing it and making sure it
springs back into place when you release it. Put safety

latch in UP position and test trigger. You should not be

able to press trigger. Replace gun immediately if it

fails any of these tests.

Check In-Line RIter

Refer to the illustration and service the in-line filter if it

becomes clogged, as follows:

In-Line Filter

Lance

O-ring

1. Detach gun and lance from high pressure hose.

Detach lance from gun and remove o-ring and

screen from lance. Flush the screen, gun, and

lance with clean water to clear debris^

2. If the screen is damaged, the o-ring kit contains a

replacement in-line filter screen and an o-ring. If

undamaged, reuse screen.

3. Place the in-line filter screen into the threaded end

of the lance. Direction does not matter. Push the
screen in with the eraser end of a pencil until it

rests flat at the bottom of the opening. Take care to
not bend the screen.

4. Piace the o-ring into the recess. Push the o-ring

snugly against the in-line filter screen.

5. Assemble the lance to the spray gun, as described

earlier in this manual.

Purge Pump of Air and Contaminants

To remove the air from the pump, follow these steps:

• Set up the cleaning system as described in the

ASSEMBLY section and connect the water supply.

• Remove the wand extension from the gun.

• Pull the trigger on the gun and hold until a steady

stream of water appears.

To remove the contaminants from the pump, follow
these steps:

• Set up the cleaning system as described in the

ASSEMBLY section, and connect the water supply.

• Remove the nozzle attachment from the gun.

• Start the engine according to instructions in

OPERATION section.

• Pull the trigger on the gun and hold.

• When the water supply is steady and constant,

engage the safety latch and refasten the nozzle
attachment.

Nozzle Maint^iance

If the nozzle becomes restricted or clogged with

foreign materiais, such as dirt, excessive pump

pressure may deveiop. A partially clogged nozzle can

cause a pulsing condition during use. This generaliy is

not a pump related problem, but rather a clogged or
partially restricted nozzle.

If the nozzle becomes clogged or partially restricted,

immediately clean the nozzle with the kit included with

your cleaning system by following these instructions:
• Shut off the engine and turn off the water supply.
• Separate the wand from the gun.

• Rotate to stream setting.

• Remove nozzle from the end of the wand using a

2mm or 5/64 alien wrench.

V