Extension Cords
If an extension cord is necessary, a cord with adequate size
conductors that is capable of carrying the current necessary for your
tool must be used. This will prevent excessive voltage drop, loss of power or overheating.
Grounded tools must use 3-wire extension cords that have 3-prong plugs and receptacles.
A WARNING
RECOMMENDED SIZES OF EXTENSION CORDS
120 VOLT ALTERNATING CURRENT TOOLS
Tool’s
Ampere
Rating
Cord Size in A.W.G.
Wire Sizes in mm^
Cord Length in Feet
Cord Length in Meters
25
SO
1(H) 150
15
30
60
120
3-6
18
16
16
14
.75 .75
1.5 2.5
6-8
18
16
14
12
.75 1.0
2.5 4.0
8-10
18
16
14
12
.75 1.0
2.5 4.0
10-12
16
16
14
12
1.0 2.5
4.0
—
12-16
14
12
—
—
—
—
—
—
NOTE: The smaller the gauge number, the heavier the cord.