MAINTENANCE cont.
DOUBLE INSULATION
Double insulation is a concept in safety in eiectric power toois, which eiiminates the
need for the standard 3-wire grounded power cord. All exposed metal parts are
isolated from the internal motor components with protectve insulation. Double
insulated tools do not need to be grounded.
IMPORTANT
The servicing of a tool with double insulation requires extreme care and knowledge
of the system and should be performed only by a qualified service technician. For
service, we recommend that you return the tool to your nearest Sears Service Center
for repair.
ALWAYS
use original factory replacement parts when servicing.
EXTENSION CORDS
The use of any extension cord will cause some loss of power. To keep the loss at a
minimum and to prevent overheating, use an extension cord that is heavy enough to
carry the current that the tool will draw.
A wire gauge (AWG) of at least 16 is recommended for an extension cord 100 feet or
I
ges
in length. When working outdoors
ALWAYS
use an extension cord that is
suitable for outdoor use. The cord's jacket will be marked WA.
A
CAUTION:
Keep extension cords away from the cutting area, and position
ihe cord so It will not get caught on lumber, tools, etc. during the cutting operation
A
DANGER;
Check extension cords before each use. If damaged, replace
it immediately.
NEVER
use a tool with a damaged cord because touching the
damaged area could cause electrical shock, resulting in serious injury.
Extension cords that are suitable for use with your saw are available at your nearest
Sears Store.
MAXIMUM STOCK SIZE & FEED RATES
C/R TYPE
MATEmAL
MAX. SIZE
iCnOBS SECTION)
MAX
THICKNESS
AVERAGE
BLADE UFE
AVERAGE
TIME cm FEED
Galvanizecj Iran
! )/?•'
t/ñ"
360 cuts
20 Sec
Square channel j..................j
M s
1 1/2*'
1/B-
140 culs
30 Sec
AlLrntinnm
1 1/2'’
1/0"
8000 cuts
5 Sec
Channel jj---------------------- 1
M.S.
1 1/2'
1/8'
120culs
30 Sec
Sheet Metal ...................
M.S.
1/8"
70 Feet
4.3 Incfi/rtiin
Aliiminnm
1/8"
112 Feet
102 Incli/mln
Stud
Wood (Pine)
2*' X 4*'
1 1/2"
10000 cuts
11 Sec
Pipe
Flastio (PVC)
1 1/2'
3/16"
12000 cuts
6 Sec
Ps.
Averiige biRdR III
r
inrIicRteR reisullis
nf
performance iKRt in parliculai type ot lesl t^iaierial as per the above table However the
rnsuHs mey very if Ihe earvie blacle Is nser! on combinolion of ilnted rnalerinlr;.
ao