beautypg.com

Storage, Maintenance, A caution – Craftsman 921.153100 User Manual

Page 8: A warning

Attention! The text in this document has been recognized automatically. To view the original document, you can use the "Original mode".

background image

Maintenance

NOTE:

Any setvice procedure not covered in the maintenance schedule below should be performed by qualified service

personnel.

Items to Check/Change

Before each

use or daily

After first

10 hours

Every

100 hours

Check Tank Safety Valve

X

Overall Unit Visual Check

X

Check Oil Level

X

Change Oil

X

X

Check Air Filter (more frequently in dusty or humid environments)

X

Drain Tank (after each use or daily)

X

A CAUTION

To ensure efficient operation and longer life of the air

compressor unit, a routine maintenance schedule should
be followed. The following schedule is geared toward a
consumer whose compressor is used in a normal working
environment on a daily basis. If necessary, the schedule
should be modified to suit the conditions under which your
compressor is used. The modifications will depend upon
the hours of operation and the working environment. Air
compressors used in an extremely dirty and/or hostile

environment will require a greater frequency of all
maintenance checks.

A WARNING

The air compressor should be turned off and unplugged
from the power source before any maintenance is

performed as well as the air bled from the tank and the
unit allowed time to cool. Personal injuries could occur
from moving parts, electrical sources, compressed air or
hot surfaces.

Oil Changing
For changing the pump oil, be sure to do the foliowing:
1. Turn the unit off and unplug the power cord from the

receptacle.

2. Allow the compressor time to cool if it has been in

operation.

3. Open the drain valve to bleed all air from the tank.
4. Close the drain valve.
5. Remove the oil fill cap on the pump.
6. Remove the sight glass with a box end wrench or

socket. Drain the oil into a suitable container and
dispose of properly. The compressor may need to be

tipped slightly towards the drain hole to aiiow all of the

oil to drain.

7.

8

.

Reattach the sight glass.

Note: Torque the sight glass

10-12 inch lbs. when re-assembling. Be sure the gasket
is between the sight glass and the pump crankcase.
Refill the compressor pump with an air compressor oil
such as SAE-30 non-detergent {API CG/CD Heavy
Duty) oil at slow intervals until the oil reaches the center
of the red circle in the sight glass. Use a SAE-10 during
extreme winter conditions.

Storage

For storing the air compressor, be sure to do the following:

1. Turn the unit off and unplug the power cord from the

receptacle.

2. Remove all air hoses, accessories, and air toois from

the air compressor.

3. Perform the daily maintenance schedule.

4. Open the drain valve to bleed all air from the tank.
5. Close the drain valve.
6. Store the air compressor in a clean and dry location.