CONGRATULATIONS on your purchase of a Sears Crafts
man Generator. It has been designed, engineered and
manufactured to give you the best possibie dependability
and performance.
Should you experience any problem you cannot easily
remedy, please contact your nearest Sears Service Cen-
ter/Department or call the 1 -800 number listed on the front
of this manual. We have competent, well-trained techni
cians and the proper tools to service or repair this unit.
Please read and retain this manuaf The instructions will
enable you to assemble and maintain your generator prop
erly Always observe the 'SAFETY RULES “
MODEL
NUMBER
SERIAL
NUMBER
580.327071
DATE OF
PURCHASE^
THE MODEL AND SERIAL NUMBERS WILL BE
FOUND ON A DECAL ATTACHED TO THE GENER
ATOR STATOR CAN
YOU SHOULD RECORD BOTH SERIAL NUMBER
AND DATE OF PURCHASE AND KEEP IN A SAFE
PLACE FOR FUTURE REFERENCE,
MAINTENANCE AGREEMENT
A Sears Maintenance Agreement is available on this prod
uct Contact your nearest Sears store for details
CUSTOMER RESPONSIBILITIES
•
Read and observe the safety rules,
•
Follow regular schedule in maintaining, caring for and
using your generator
» Follow the instructions under "Maintenance" and "Stor
age" sections of this Owner's Manual
PRODUCT SPECIFICATIONS
Generator Specifications
RATED MAXIMUM
POWER
8000 Watts (8.0 kW)
RATED VOLTAGE
120/240 Volts a-C
RATED MAXIMUM
LOAD CURRENT
66.7/33.3 a-c amperes
RATED FREQUENCY
60 Hz at 3600 rpm
PHASE
Single Phase
BATTERY CHARGE Amps;
Volts:
10 DC amps
12 volts DC
Engine Specifications
ENGINE MODEL
GN-Series
DISPLACEMENT
480cc
SPARK PLUG: Type:
Set Gap to:
Champion RC12YC or
or equivalent
0.030 inch (0.76mm)
MAXIMUM FULL TANK
OPERATING TIME (hrs)
full load 1/2
5 7
GASOLINE CAPACITY
5 U.S. gallons
OIL
SAE 30 Oil
(SAE 10W-30)
OIL CAPACITY
56 oz with oil filter
46 oz without filter
NOTE: This generator Is equipped with a spark arrestor
muffler The spark arrestor must be maintained in effective
working order by the owner/operator
In the State of California a spark arrestor is required by law
(Section 4442 of the California Public Resources Code),
Other states may have similar laws Federal laws apply on
federal lands