Radiance direct vent gas heater – Vermont Casting RADVTCBB User Manual
Page 37
37
Radiance Direct Vent Gas Heater
20012697
2. Remove and replace plug on lower right hand side
of the valve; Red for LP and Blue for NG. (Page 32,
Fig. 57)
3. Remove motor top cap using a standard slotted
screwdriver. Depress and turn center plunger until
arrow points to correct screw. Red for LP and Blue
for NG. NOTE: Plunger will “snap” into NG position
when arrow is close to blue screw. It will not “snap”
at LP (Red) position. (Fig. 66)
CO105a
gas conversion
Pilot
1/28/00 djt
Pilot Hood
Pilot
Bracket
CO105a
Fig. 68 Remove pilot hood.
CO106a
DV360/580
Gas Conversion
Pilot2
1/28/00 djt
Index Tab
Snap Ring
Allen Wrench
CO106a
Fig. 69 Remove pilot orifice.
ST350
Jefferson
air shutter adj
3/20/00 djt
Pilot
ST916
Fig. 67 Locate pilot.
CO142
Rf pilot Conversion
6/07 djt
Pilot Hood
Index
Marks
Pilot Bracket
CO143
Fig. 70 Remove pilot hood. (Your pilot may have a different
appearance.)
FP1037b
comfort valve
convert
3/6/01 djt
LOCAL
REMOTE
O
N
•
PILO
T
OFF
•
LED
Motor Top Cap
Center
Plunger
Blue - NG
Red - LP
FP1037b
Fig. 66 Depress and turn center plunger.
Valve
4. Insure manifold pressure remains between 3.2” - 3.5”
w.c. for NG and 9.5” - 10” w.c. for LP. To adjust the
manifold pressure, for NG, using a Torx #10 key turn
the blue screw clockwise to increase the manifold
pressure. Turn the screw counterclockwise to de-
crease the pressure. Use the red screw to adjust LP.
5. Replace motor top cap.
Pilot Orifice Conversion
1. Locate pilot. (Fig. 67)
2. Replace pilot orifice.
Pilot Type 1 (SIT Pilot)
•
Remove pilot hood by lifting up. (Fig. 68) Do not
remove the snap ring to remove the pilot hood.
NOTE: It is not necessary to remove the pilot tube
for conversion.
•
Remove pilot orifice with Allen wrench. (Fig. 69)
•
Install the conversion orifice.
•
Reinstall pilot hood. Be sure to align hood with
index tab.
Pilot type 2 (Honeywell Pilot)
•
Loosen pilot hood turning counterclockwise using a
7/16” wrench. (Fig. 70) NOTE: You may use pen-
etrating oil to prevent pilot hood threads from seizing
up.
•
Remove pilot orifice with needlenose pliers. (Fig.
71) NOTE: Use a wrench to hold pilot tube in place
while removing the orifice.
•
Install the conversion orifice.
•
Reinstall pilot hood and tighten until mark on pilot
hood aligns with mark on pilot bracket.