Grounding Instructions

TO pREVENT ELEcTRIc SHOcK AND DEATH FROM INcORREcT GROUNDING WIRE cONNEcTION

READ AND FOLLOW THESE INSTRUcTIONS:

110-120 V~ Grounded Tools: Tools with Three prong plugs

1. In the event of a malfunction or breakdown,

grounding provides a path of least resistance for

electric current to reduce the risk of electric shock.

This tool is equipped with an electric cord having an

equipment-grounding conductor and a grounding

plug. The plug must be plugged into a matching

outlet that is properly installed and grounded in

accordance with all local codes and ordinances.

2. Do not modify the plug provided – if it will

not fit the outlet, have the proper outlet

installed by a qualified electrician.

3. Improper connection of the equipment-grounding

conductor can result in a risk of electric shock.

The conductor with insulation having an outer

surface that is green with or without yellow

stripes is the equipment-grounding conductor.

If repair or replacement of the electric cord or

plug is necessary, do not connect the equipment-

grounding conductor to a live terminal.

4. Check with a qualified electrician or service

personnel if the grounding instructions are

not completely understood, or if in doubt as

to whether the tool is properly grounded.

5. Use only 3-wire extension cords that

have 3-prong grounding plugs and 3-pole

receptacles that accept the tool’s plug.

6. Repair or replace damaged or worn cord immediately.

125 V~ 3-prong plug and Outlet

(for up to 125 V~ and up to 15 A)

Grounding

pin

7. This tool is intended for use on a circuit

that has an outlet that looks like the one

illustrated above in

IMpORTANT SAFETy

INSTRUcTIONS. The tool has a grounding

plug that looks like the plug illustrated above

in

IMpORTANT SAFETy INSTRUcTIONS.

8. The outlet must be properly installed and grounded

in accordance with all codes and ordinances.

9. Do not use an adapter to connect

this tool to a different outlet.

Functional Description

Specifications

Electrical Rating

120V~ / 60Hz / 40W (Light)

120V~ / 60Hz / 12A (Motor)

Fluorescent Bulb 18W, 23″ L x 1″ Dia. (Qty. 2)

Working Pressure 50 ~ 125 PSI

Air Consumption 13 ~ 15 CFM @ 80 PSI

Air Inlet Size

3/8″-18 NPT

Abrasive Capacity Approximately 15 lb.

Inner Cabinet

47-3/4″ W x 24″ D x 22-1/2″ H (Rear), 14″ H (Front)

Front Window

22-1/2″ W x 10-1/2″ H

Accessories

4mm, 5mm, 6mm & 7mm Ceramic Nozzles