Chateau – Vermont Casting ChateauTM DVT38IN User Manual
Page 41
![background image](/manuals/62834/41/background.png)
41
Chateau™
20011956
Pilot Flame Adjustment
Typically, the top 3/8” or 1/2” of the pilot flame sensor
should be engulfed in the pilot flame. (Page 33, Fig. 55)
To adjust pilot burner:
1. Locate pilot adjustment screw on the valve next to
the black plastic cap. Refer to Page 35.
2. Adjust pilot screw to provide proper sized flame.
Only a small adjustment should be needed.
NOTE: Do not rotate screw excessively. Do not adjust
any other screws on the valve.
Conversion to LP
Burner Orifice
Input (BTU/hr)
Kit #
Model
Front
Part #
Middle
Part #
Rear
Part #
Minimum Maximum
20011992
DVT38IP
#66
20009182
#59
20000664
#50
30000337
34,000
46,000
(.033”)
(.041”)
(.070”)
20012367
DVT44IP
#63
20006251
#57
20004587
#49
20006252
45,000
60,000
(.037”)
(.043”)
(.073”)
Table 1 Injector Orifice Size Matrix
Conversion to LP
Burner Tube
Burner Housing
Model
Air Shutter Setting
Air Shutter Setting
DVT38IP
Fully open
n/a
DVT44IP
Fully open
Fully open
Table 2 Air Shutter Settings
2
Table 3 Valve Minimum Rate Screw
Model
Size
Part #
DVT38IP
#31 (.120”)
20012364
DVT44IP
No Shank Screw
20012264