beautypg.com

Chimney requirements - offset installations, Vermont castings ewf36a, Illustration key – Vermont Casting EWF36 User Manual

Page 6: 30˚ elbow offsets

background image

6

Vermont Castings EWF36A

20005167

D

Rise

B

G

H

B

Offset

C

E

6 FT.

G

H

A

Hearth

Floor

Chimney

Section

CHIMNEY FLUE EXIT

Elbow

FP269
MBUF

5/16/96

rev. 5/25

TCS8A

Support

Example 1

Example 2

Example 3

Chimney Requirements - Offset Installations

Notes: G + H cannot exceed 20 feet.

Air Space Clearances: “S” Series (3-wall) = 2” Min. to Combustibles

Illustration Key

The following safety rules apply to
offset installations (letters correspond
with illustration above):
A. Height of the chimney is measured
from the hearth to the chimney exit.

EWF36A

Maximum:

50’

Minimum:
Without Elbows

17’0”

With 2 Elbows*

19’0”

With 4 Elbows*

21’0”

B. Do not use more than 4 elbows per
chimney.
Attach the straps of the return (top)
elbow to a structural framing member.
The offset (first) elbow of any pair does
not have straps.

FP269

C. The chimney cannot be more than 30˚
(45˚ in Canada) from the vertical plane in
any installation*.
D. The maximum length of the angled run
of the total chimney system is 20 feet. (G
plus H cannot exceed 20 feet.)
E. A chimney support (Model TCS8A)
is required every 6 feet of angled run of
chimney. Chimney supports are required
for every 30 feet and 60 feet of vertical
chimney height above the hearth.
Determine the offset distance of your
chimney arrangement from the centerline
of the fireplace to the centerline of the
chimney where it is to pass through the
first ceiling.

NOTE: This offset distance may not be
your full offset distance. See Examples 2
and 3.

Fig. 3 Chimney system requirements.

FP282

0 0 0 0 0

3”

11”

1 0 0 0 0

8¹⁄₄"

20"

0 1 0 0 0 11¹⁄₄" 25¹⁄₄"
2 0 0 0 0 13¹⁄₂" 29¹⁄₄"
1 1 0 0 0 16¹⁄₂" 34¹⁄₄"
0 0 1 0 0 20¹⁄₄" 40³⁄₄"
2 1 0 0 0 21³⁄₄" 43¹⁄₂"
0 0 0 1 0 26¹⁄₄" 51¹⁄₄"
0 1 1 0 0 28¹⁄₂" 55¹⁄₄"
1 0 0 1 0 31¹⁄₂" 60¹⁄₄”
0 1 0 1 0 34¹⁄₂" 65¹⁄₂"
0 0 2 0 0 37¹⁄₂" 70³⁄₄"
1 1 0 1 1 41¹⁄₂" 77³⁄₄"
0 0 1 1 1

45" 83³⁄₄"

0 1 2 0 1 47¹⁄₄" 87¹⁄₂"
0 0 0 2 1

51"

94"

0 1 1 1 1 53¹⁄₄"

98"

0 0 3 0 1 56¹⁄₄" 103¹⁄₄"
0 1 0 2 1 59¹⁄₄" 108¹⁄₂"
0 0 2 1 1 62¹⁄₄" 113¹⁄₂"
0 1 3 0 1 64¹⁄₂" 117¹⁄₂"
0 0 1 2 1 68¹⁄₄"

124"

0 1 2 1 1 70¹⁄₂"

128"

0 0 0 3 1 74¹⁄₄" 134¹⁄₂"
0 1 1 2 2

78" 140³⁄₄"

0 0 3 1 2

81"

146"

0 1 0 3 2

84" 151¹⁄₄"

0 0 2 2 2

87" 156¹⁄₂"

0 1 3 1 2 89¹⁄₄" 160¹⁄₄"
0 0 1 3 2

93" 166³⁄₄"

0 1 2 2 2 95¹⁄₄" 170³⁄₄"
0 0 0 4 2 99¹⁄₄" 177³⁄₄"
0 1 1 3 2 101¹⁄₄" 181³⁄₄"
0 0 3 2 2 104¹⁄₄" 186¹⁄₄"
0 1 0 4 2 107¹⁄₄" 191¹⁄₂"
0 0 2 3 2 110¹⁄₄" 196³⁄₄"
0 1 3 2 3

114" 203¹⁄₄"

0 0 1 4 3 117³⁄₄" 209³⁄₄"
0 1 2 3 3

120" 213¹⁄₂"

0 0 0 5 3 123³⁄₄"

220"

30˚ Elbow Offsets

1’ 1¹⁄₂' 3’ 4’

Chimney

Support

Offset

Rise

FP282

MBUF

5/26/96

Offset

Rise

30°

Return

Elbow

30°

Return

Elbow

30°

Offset

Elbow

30°

Offset

Elbow