PulseTech 490PT+ 12V Digital Battery Analyzer Tester & Printer (741X491) User Manual
Page 8

www.pulsetech.net
7
10. When the test is completed, the display shows the
actual volts and the actual CCA or %. {Press the
''UP/DOWN'' key to select SOH (STATE OF HEALTH) or
SOC (STATE OF CHARGE)}.
One of three results will be displayed:
GOOD & PASS :
The battery is good & capable of
holding a charge.
GOOD & CHARGE :
The battery is good but needs to be
recharged.
CHARGE & RETEST :
Battery is discharged, the battery
condition cannot be determined until
it is fully charged. Recharge & retest
the battery.
LOAD ERROR :
The tested battery is bigger than 2000 CCA or 200AH.
Or the clamps are not connected properly. Please fully
charge the battery and retest after excluding both previous
reasons. If reading is the same, the battery should be
replaced immediately.
11. Press the ''UP/DOWN'' key to select result printing:
YES or NO. Press "ENTER" to confirm your choice.
12. NO: Press "ENTER" return to step 5 or remove the test
clamps from the battery posts after completion of testing
batteries to end test.
GOOD & PASS
XX.XX V XXXX CCA
GOOD & CHARGE
XX.XX V XXXX CCA
CHARGE & RETEST
XX.XX V XXXX CCA
-7-