beautypg.com

Mains electricity connection – CDA INDUCTION HOB HVN61/81 User Manual

Page 13

background image

Mains Electricity Connection

Warning! this appliance must be earthed

We recommend that the appliance is connected by a qualified electrician, who is a member of the N.I.C.E.I.C. and who
will comply with the I.E.E. and local regulations.

This appliance is intended to be connected to fixed wiring and is not suitable for connection to a 13a plug or
13a supply.

This appliance is intended to be connected to fixed wiring by a double pole switch, having a contact separation of at
least 3mm in all poles. The switch must be positioned no further than 2m from the appliance.

This appliance is supplied with a 3 core mains cable; the wires are in accordance with the following code:

Green & Yellow = Earth

Blue = Neutral

Brown = Live

Please note:

• The mains cable must only be replaced by a qualified service engineer and must be of equivalent or

better rating (i.e. 2.5mm

2

, HO5V2V2-F).

• This appliance is intended to be connected to the mains supply with a cable of cross section area 2.5 mm2. A larger

cable will not fit the terminal connections.

• The marking of the current rating of the fuse or circuit breaker protecting this appliance should be marked on the

socket outlet.

• Assembly and electrical connection should be carried out by specialised personnel.

• When installing this product we recommend you seek the help of another individual.

Fig.7

Black - grey

Green / yellow

Blue

Brown

N

L

Green / yellow

Blue

Brown

N

L

Use a 32A circuit breaker or fuse

or