Physical — Enclosure
Depth
75.5 cm (29.7 inch)
Weight (maximum)
200.5 kg (442 lb)
Weight (empty)
44.6 kg (98.1 lb)
Environmental
NOTE: For additional information about environmental measurements for specific system configurations, see
dell.com/environmental_datasheets.
Temperature
Operating
Continuous operation: 10 °C to 35 °C at 10% to 80%
relative humidity (RH), with 26 °C max dew point. De-rate
maximum allowable dry bulb temperature at 1 °C per 300
m above 900 m (1 °F per 550 ft).
NOTE: For information on supported expanded
operating temperature range and configurations, see
support.dell.com/manuals.
Storage
–40 °C to 65 °C (–40 °F to 149 °F) with a maximum
temperature gradation of 20 °C per hour
Relative humidity
Operating
10% to 80% relative humidity (RH), with 26 °C max dew
point
Storage
5% to 95% (noncondensing) at a maximum wet bulb
temperature of 38 °C (100.4 °F)
Maximum vibration
Operating
0.26 G
rms
at 5 Hz to 350 Hz for 15 min
Storage
1.54 G
rms
at 10 Hz to 250 Hz for 15 min
Maximum shock
Operating
One shock pulse in the positive z axis (one pulse on each
side of the system) of 31 G for up to 2.6 ms
Storage
Six consecutively executed shock pulses in the positive
and negative x, y, and z axes (one pulse on each side of
the system) of 71 G for up to 2 ms
Altitude
Operating
–15.2 m to 3048 m (–50 ft to 10,000 ft)
NOTE: For altitudes above 2950 ft, the maximum
operating temperature is derated 1 ºF per 550 ft.
Storage
–15.2 m to 10,668 m (–50 ft to 35,000 ft)
Airborne Contaminant Level
Class
G1 as defined by ISA-S71.04-1985