Enabling and Disabling DPAT Using WSMAN

To enable or disable DPAT using WSMAN, run the following command:

winrm i SetAttribute

http://schemas.dmtf.org/wbem/wscim/1/cim-

schema/2/root/dcim/DCIM_BIOSService?SystemCreationClass

Name=DCIM_ComputerSystem+CreationClassName=

DCIM_BIOSService+SystemName=DCIM:ComputerSystem+Name=

DCIM:BIOSService -u:%1 -p:%2 -r:https://%3/wsman -

SkipCNcheck -SkipCAcheck -SkipRevocationCheck -

encoding:utf-8 -a:basic -file:set_controlled_turbo.xml

NOTE:

Replace %1 with iDRAC userID, %2 with iDRAC password and %3 with the

iDRAC IP.

Enabling Turbo Using WSMAN

To enable turbo using WSMAN, use the following content for

set_controlled_turbo.xml:

"http://schemas.dmtf.org/wbem/wscim/1/cim-
schema/2/root/dcim/DCIM_BIOSService">

BIOS.Setup.1-1

ControlledTurbo

Enabled

Disabling Turbo Using WSMAN

To disable turbo using WSMAN, use the following content for

set_controlled_turbo.xml:

"http://schemas.dmtf.org/wbem/wscim/1/cim-
schema/2/root/dcim/DCIM_BIOSService">

BIOS.Setup.1-1

ControlledTurbo

Disabled

Pro.fm Page 11 Tuesday, March 5, 2013 3:27 PM