Updating BIOS on Dell 12G PowerEdge Servers
26
2 = Graceful shutdown and reboot (Recommended)
3 = Forceful shutdown if graceful shutdown does not succeed
4 = No reboot
9. The script prompts for deleting all existing jobs in iDRAC. Dell recommends that you choose
“yes” to have a clean start.
Erase all previous jobs stored in the iDRAC? (yes/no) yes
Deleting all iDRAC jobs
Completed job deletion
10. The script prompts you to specify the start time for the job. The job can be scheduled either
immediately or for a future time.
Schedule the bios update now or schedule later (now, schedule)? now
The format of the StartTime argument is defined by the CIM Infrastructure Specification. Select
the “now” option to schedule the jobs immediately. Use the “schedule” option to schedule the
job for a future time. The “schedule” option will prompt for a start time, which should be of the
format MM-DD-YYYY hh:mm:ss
Y = Year, M = Month, D = Day, H = Hour, m = minute, S = second
12-13-2011 11:11:11
Once the start time is specified, the Update job is initiated.
11. The update package is downloaded from the repository and may take some time depending on
the size of the package and network state.
12. Once the update package is successfully downloaded, the update and the reboot job are
scheduled for the specified start time.
The following is a sample output:
bios update successfully created
Creating reboot job
Reboot job successfully created.
Scheduling bios update job
Scheduling reboot job
The bios updating from version 1.0.4 to version
tftp://192.168.0.100/BIOS_VT7R8_WN32_1.1.0.EXE
Check the status of the reboot job and the bios update job by using the fw_pull.py
script.