Trouble shooting the gas control system – Vermont Casting DBR36 User Manual
Page 23

- 23 -
GAS SUPPLY ON
• SUPPLY LINE HOOKED UP
• SHUTOFF VALVE OPEN
NO
NO
NO
NO
• LOCKOUT HAS ENGAGED. WAIT 
 60 SECONDS AND TRY AGAIN.
• PIEZO NOT TIGHT ENOUGH 
 FOR GOOD GROUND.
• FOR SPARK AT ELECTRODE 
 WHILE DEPRESSING PIEZO 
 (RED BUTTON) — 1/8" GAP TO 
 PILOT HOOD NEEDED.
• ALL WIRING CONNECTIONS
• REPLACE PIEZO IGNITOR
• THERMODISK
• FOR AIR IN THE LINES
• THERMOPILE NEEDS A 
 MINIMUM 325mV. ADJUST 
 PILOT FLAME HEIGHT.
• ALL WIRING CONNECTIONS.
• REPLACE THERMOPILE
• THERMOCOUPLE NEEDS A 
 MINIMUM OF 14mV.
• DEFECTIVE VALVE. TURN TO 
 PILOT, METER SHOULD READ 
 GREATER THAN 100 mV. IF 
 NOT, REPLACE.
• THERMODISK 
PILOT LIGHTS WITH
PIEZO IGNITOR
YES
YES
YES
YES
PILOT STAYS LIT
PILOT LIGHTS MAIN
BURNER
SYSTEM OK.
START
CHECK
• WALL SWITCH IS NOT
 TURNED ON. WATCH 
 FOR GROUNDED WIRES!
•THERMOPILE NEEDS A 
 MINIMUM 325mV.
• PLUGGED BURNER ORIFICE.
TROUBLE SHOOTING THE GAS CONTROL SYSTEM
HONEYWELL MILLIVOLT VALVE