Troubleshooting, Operator’s manual, Operators troubleshooting guide – Cleveland Range PEM User Manual

Page 14

background image

Operator’s Manual

P/N-260APC-A

______________________________________________________________________________

14

Troubleshooting

OPERATORS TROUBLESHOOTING GUIDE

This troubleshooting guide includes a list of
symptoms that may be encountered during the
operation and maintenance. The first column on the
left (problem) describes these symptoms. The second
column lists possible causes for the problem listed in
column one. The third column lists remedies for the
problems and causes columns one and two. The
causes and remedies are listed in the am

Or they should be checked, with the least costly and
easiest to repair listed first. The third column also
refers to notes that are grouped at the end of the
troubleshooting guide. Refer to these notes when
instructed to do so. Do not try to correct a problem
that requires an authorized service representative as
this may adversely affect warranty coverage.

PROBLEM

POSSIBLE CAUSE

REMEDY/REFERENCE

Switch light does not turn on:

Power turned off at main disconnects,

Turn on power at main disconnect switch.

When POWER switch is pressed switch.

SWITCH

On.

POWER switch light on and

Water supply to steamer shut off.

Open water supply valves.

Steam generator does not fill.

Water line strainer is clogged.

Clean water supply strainer

Water sensors shorted by scale,

Descale steam generator with USDA

Deposits.

Approved descaler.

Inoperative controls or solenoid

See note #1.

Steam Generator does not make

No water in steam generator.

See steam generator does not fill (above).

any steam.

Gas models only

Turn off steam generator and open gas

Gas supply valve closed.

supply valve. Refer to Service Manual.

Electric models only

Descale steam generator with USDA

Heating elements covered with

approved descaler

Scale.

Electric models only

See note #1.

Heating elements damaged.

Water sensors covered by scale

Descale steam generator with USDA

Deposits.

Approved descaler.

Inoperative controls.

See note #1.

Abnormal amount of steam

hot water instead of cold water

Make proper connections. Refer to

Coming from drain.

Connected to condenser fitting

Service Manual.

Water supply to condenser turned

Open water supply valve.

off.

Condenser waterline strainer

Clean out condenser water supply line.

is clogged.

See note #1.

Water supply line to the con-

Repair or replace solenoid. See note #1.

Condenser blocked, broken, or
leaking.

Inoperative condenser solenoid.

Replace solenoid. See note #1.

Inoperative five controls.

Turn off electricity at main disconnect
Switch.

See note #1.

Steam and I or water draining

Drain clogged or covered.

Clean drain with USDA approved drain

around compartment door

cleaner.

Door gasket or door parts worn.

See note #1