Electrical Installation
For your safety please read the following information:
WARNING! Before effecting any intervention on the electrical parts the appliance must be 
disconnected from the network.
IMPORTANT: The oven must be installed in accordance with the manufacturer’s instructions. 
Incorrect installation, for which the manufacturer accepts no responsibility, may cause 
damage to persons, animals and things.
General
– The connection to the electrical network must be carried out by qualified personnel and must be 
according to existing norms.
– The appliance must be connected to the electrical network verifying above all that the voltage
corresponds to the value indicated on the specifications plate and that the cables section of the electrical 
plant can bear the load which is also indicated on the plate.
– The appliance can be connected directly to the mains placing an omnipolar switch with minimum
opening between the contacts of 3 mm between the appliance and the mains.
– The power supply cable must not touch the hot parts and must be positioned so that it does not exceed
75°C at any point.
– Once the appliance has been installed, the switch must always be accessible. 
– If the power supply cable is damaged it must be substituted by a suitable cable.
IMPORTANT: this double oven must be connected to a suitable double pole control unit 
adjacent to the oven.
NO DIVERSITY CAN BE APPLIED TO THIS CONTROL UNIT.
The connection of 
the appliance to the 
grounding unit is 
mandatory. 
The manufacturer 
declines every 
responsability for 
any inconvenience 
resulting from the 
inobservance of this 
condition. 
Feeder Cable Section
Type H05RR-F or H05VV-F
230 V~ 
3 x 2.5 mm
2
(**)
(**) – Connection to wall-mounting distribution panel.