SPACE FOR FIXING
The cooker can be close fitted below hotplate level. This requires a
minimum distance of 600mm between cupboard units of hotplate height.
When installing next to a tall cupboard, partition or wall, for a minimum
distance of 400mm above hotplate level, allow a side clearance of at least
65mm.
The diagram below illustrates the minimum clearance between the cooker
and adjacent walls, cupboards etc.
The wall behind the cooker between the hotplate and 450mm above, and
the width of the cooker, must be a non-combustible material such as
ceramic wall tiles.
If the cooker is to
be fitted close to a
corner base unit on
the left hand side,
ensure that there is
a clearance of at
least 50mm to
allow the oven
door to open fully
for when removing
oven shelves.
COOKER HOODS
If a cooker hood is to be installed, refer to the cooker hood manufacturers’
instructions regarding fixing height.
UNPACKING THE COOKER
Unpack the components from inside the grill and oven: Check that the
following parts are present:
Grill pan and grid
Meat pan
Pan supports (4)
Main oven shelves (2)
Enamelled burner caps (4)
Literature
Aluminium burner bodies (4)
Anti Splash tray
26
INSTALLATION INSTRUCTIONS
65 mm Min
840 mm Min
400 mm Min
600 mm Min
750