Quick service guide, Uick service guide, Maintenance 4.2. quick service guide – CMA Dishmachines L-1X16 User Manual
Page 12
Maintenance
4.2.
Quick service guide
MODEL L-1X & L-1X16 PARTS MANUAL Rev. 1.14
Page
11
MODELS: L-1X, L-1X16 UNDER COUNTER
TECHNICAL ISSUE
CAUSE
SOLUTION
Delimer switch in delime position
Flip to
NORMAL
position
Wash Pump motor will not shut off
Faulty delimer switch
Replace switch, P/N 00475.30
Faulty manual drain switch
Replace switch, P/N 03406.62
Faulty contactor
Replace contactor, P/N 00404.82
Continues cycles
Faulty #1 micro switch (start/stop)
Replace switch, P/N 00411.00
Faulty start/fill switch
Replace switch, P/N 03470.01
Faulty #1 micro switch
Replace switch, P/N 00411.00
Low water level inside machine
Add water to tank to activate float switch, adjust
water cam on timer
Sustainer heater not working
Faulty float switch
Replace switch, P/N 13463.10
Machine not level
Level machine
Faulty ice cube relay
Replace relay, P/N 00631.00
Machine does not drain
Faulty #3 micro switch (drain)
Replace switch, P/N 00411.00
Faulty drain valve
Replace drain valve, P/N 04103.00
Does not hold water
Faulty #3 micro switch (drain)
Replace switch, P/N 00411.00
Clogged or defective drain valve
Clean and/ or replace drain valve, P/N 04103.00
Tank overflows overnight
Debris in water Solenoid Valve
Clean and replace valve diaphragm, P/N
00707.00
Water leaks out of Vacuum Breaker
Dirty or defective vacuum breaker kit
assy
Clean or replace internal parts, P/N 03623.00
Faulty check valve
Replace check valve, P/N 00715.00
Male/ female plug on the back of control
drawer is loose
Secure plug
Wash Pump motor not running
Faulty door reed switch
Replace reed switch, P/N 00557.55
Faulty 7th micro switch
Replace switch, P/N 00411.00
Faulty motor contactor
Replace contactor, P/N 00404.82
Faulty Start/Fill Switch
Replace switch, P/N 03470.01
Timer does not rotate
Faulty #1 micro switch
Replace switch, P/N 00411.00
Faulty timer motor
Replace motor assembly, P/N 00501.00
Faulty #4 Micro switch
Replace switch, P/N 00411.00
Machine does not fill
Debris inside water solenoid valve or
Faulty valve
Clean and replace valve diaphragm, P/N
00707.00
Faulty water solenoid coil
Replace solenoid coil, P/N 00738.10
Delimer switch in wrong position
Switch to
NORMAL
position
Sanitizer pump does not run
Faulty 5th micro switch
Replace switch, P/N 00411.00
Faulty sanitizer pump motor