REPRESENTATIVE ILLUSTRATION

WARNING

Spider’s nests or wasp’s mud inside the venturi may cause
fire at the valve. If a fire occurs, immediately turn off the
gas supply at the L.P. cylinder valve (see representative
illustration in Fig. 29).

Note:

Spiders and small insects can spin webs and build nests inside the
venturi tubes. This especially occurs in late summer and fall before
frost when spiders are most active. These nests can obstruct gas
flow and cause a fire in and around the burner valves. Such a fire
can cause operator injury and serious damage to the grill. To help
prevent a blockage and ensure full heat output, clean and inspect
the venturi tubes often (once or twice a month). NOTE: Water or air
pressure will not normally clear a spider web.

Fig. 29

Cleaning the Venturi

Steps For Cleaning Venturi:

1. To remove the above obstructions, use an accessory flexible venturi

brush or bend a small hook on one end of a 20-inch long flexible wire
such as the one shown in Fig. 30.

Fig. 30

2. Remove the cooking grates set aside (Fig. 31).

Fig. 31

Spring

Latch

Fig. 32

3. Using a screwdriver, remove the screws holding the heat tents

and set aside (Fig. 32).

Fig. 33

4. Using a screwdriver, remove the self-tapping screws holding

the burner clamps and remove the burners (Fig. 33).

5. Look inside lower end of venturi tubes for nests, webs or mud.

If present, clean as shown in Step 1, Fig. 30.

6. Inspect and clean the burner if needed.
7. Replace the main burners and burner clamps, and position the

burners in the operating position.

8. Make sure the valve orifices are inside the venturi tubes and

the venturi tubes are inside the burner tubes, then tighten all
self-tapping screws (Fig. 34).

9. Reinstall the heat tents and the cooking grates.

Fig. 34

Burner Tube

Venturi

Tube