Light Control Rocker Switch Connections
The following diagram shows proper connection of the rocker switch leads located at the rear.
Note: Negative (NEG) connection must also be made on 10-Pin plug for rocker switches to light
up.
WARNING: The lighting control circuits of this unit are not fused. Automotive fuses or circuit
breakers must be connected between the power source and the unit properly rated for the circuit
requirements. Failure to install proper circuit breakers or fuses can result in damage to the unit
and/or vehicle.
GRN
Recommended
Wire Size
Amps
Size
5 - 10
#16
10 - 15
#14
15 - 30
#12
30 - 40
#10
40 - 50
#8
50 - 60
#6
Use next larger size
if longer than 10 ft.