LIGHT CONTROL CONNECTIONS

In addition to these instructions a label located on the bottom of the unit shows the light control
switch connections.

Fuses / Breakers
The lighting control circuits of this unit are not fused. Automotive fuses or circuit breakers must
be connected between the power source and the unit properly rated for the circuit requirements.
Failure to install proper circuit breakers or fuses can result in damage to the unit and/or
vehicle.

Lever Switch Connections

The following diagram shows proper connection of the lever switch leads located at the rear.

Note: Negative (NEG) connection must also be made on 10-Pin plug for proper operation.

Recommended

Wire Size

Amps

Size

5 - 10

#16

10 - 15

#14

15 - 25

#12

25 - 40

#10

40 - 60

#8

60 - 80

#6

Use next larger size

if longer than 10 ft.

YEL

GRN

BLU

RED

Circuit Breaker

or Fuse

60 AMP Max.

LOAD 1

LOAD 2

LOAD 3

+

BATT

-

Lever

Position

Turns

On

Off

All off

1

Load 1 only

2

Loads 1 and 2

3

Loads 1, 2 and 3

Off 1 2 3