Proper usage, Control & function, Dipswitch chart – Chauvet SCORPION LRG-55 User Manual
Page 9: Roper, Sage, Ipswitch, Hart, Ontrol, Unction
Proper Usage
This unit has been designed to be hung. It is recommended that, for safety purposes, your
lighting effect are properly mounted using a suitable hanging clamp and safety cable.
CHAUVET offers a range of items, which are ideal for safe mounting.
It is the responsibility of the manufacturer to provide useful instruction on the proper use of
this product. According to FDA Regulations you should operate the product in the fashion
illustrated below.
CAUTION: Use of controls, adjustments, or performance of
procedures other than what is specified herein may result in
hazardous radiation exposure
C
ONTROL
&
F
UNCTION
This unit uses dipswitches to assign a units function, DMX address and DMX MODE of function. Each
dipswitch represents a binary value.
Dipswitch Chart
0=OFF 1=ON X=0FF or ON
DIPSWITCH CHART
FUNCTION
1 2 3 4 5 6 7 8 9 10 11 12
X X X X X X X X X 0 0 0
SOUND
ACTIVE
X X X X X X X X X 0 0 1
AUTO
MODE
X X X X X X X X X 0 1 0
MASTER_SOUND
X X X X X X X X X 0 1 1
MASTER_AUTO
X X X X X X X X X 1 0 0
SLAVE
SET DMX ADDRESS
1
0
1
DMX MODE
X X X X X X X X X 1 1 0
TEST
MODE
Function chart
Dipswitches #10,#11,and #12 is set system function, from #1 to #9 is set
DMX512 address in DMX MODE.
LRG-55 User Manual
9
11/14/2007/18:46