DMX Channel Values

Channel Value Function

1

000

Щ 010

011

Щ 120

121

Щ 250

251

Щ 255

Mode
Laser off
Dynamic Patterns
Static Patterns
Sound Active Mode

2

000

Ù 255

Pattern Selection
Static Patterns – Dynamic Patterns

3

000

Ù 255

X Position
Left > Right

4

000

Ù 255

Y Position
Top > Bottom

5

000

Ù 255

Scan Speed
Fast > Slow

6

000

Ù 255

Dynamic Pattern Speed Control
Fast > Slow / See page 16

7

000

Ù 255

Static Pattern Size Control
Small > Big / See page 17

8

000

Щ 100

101

Щ 200

201

Щ 255

Color
Green & Red ON
Green
Red

NOTES

Some Static patterns can adjust both in size and position.


Trouble Shooting

CAUTION: Use of controls, adjustments, or performance of procedures other
than what is specified herein may result in hazardous radiation exposure

1)

If the power supply indicator does not light up and the laser does not work, please check if the
power supply and the corresponding parts have the right input electric current.

2)

If it is in stand-alone mode operation, the power supply indicator is lit and the laser is not
working, please check if the operation system is set up in Master/Slave mode.

3)

If it is in Master/Slave mode, Slave mode is exceptional, please check as below:
A. Make sure to set up Master mode for just one unit and the others are set in slave mode.
B. Make sure to control the unit with DMX controller.
C. Make sure to take a good quality power cord and connection.

4)

If the unit is in DMX mode, the laser cannot be controlled by the DMX controller, and the DMX
signal indicator is not illuminated please check as below:
A. Make sure to set up the DMX mode.
B. Make sure to have a good connection.

5)

If it is in DMX mode, the laser is cannot be controlled by the DMX controller but the DMX signal
indicator flashes, please make sure the DMX controller and the laser have the same DMX
Address.

6)

If the no laser outputs from the projector please restart the AC power by turning off the AC
switch and leaving off for 15 seconds and then turning the switch back to the on position.

7)

If the test pattern is not in the proper position restart the AC power by turning off the AC switch
and leaving off for 15 seconds and then turning the switch back to the on position.

After trying the above solution you still have a problem, please contact CHAUVET.