beautypg.com

Dell PowerEdge R905 User Manual

Page 15

background image

Getting Started With Your System

13

Environmental

NOTE:

For additional information about environmental measurements for specific

system configurations, see www.dell.com/environmental_datasheets.

Temperature

Operating

10° to 35°C (50° to 95°F)

Storage

–40° to 65°C (–40° to 149°F)

Relative humidity

Operating

20% to 80% (noncondensing) with a
maximum humidity gradation of 10%
per hour

Storage

5% to 95% (noncondensing)

Maximum vibration

Operating

0.26 Grms (10 to 350 Hz)

Storage

1.54 Grms (10 to 250 Hz)

Maximum shock

Operating

One shock pulse in the positive z axis
(one pulse on each side of the system)
of 41 G for up to 2 ms

Storage

Six consecutively executed shock pulses
in the positive and negative x, y, and z axes
(one pulse on each side of the system)
of 71 G for up to 2 ms

Altitude

Operating

–16 to 3048 m (–50 to 10,000 ft)

Storage

–16 to 10,600 m (–50 to 35,000 ft)

Airborne Contaminant Level

Class

G2 or lower as defined by ISA-S71.04-1985