Packaged terminal air conditioner (ptac), Rearward slope – FRIGIDAIRE FRP77PTT2A User Manual

Page 3

background image

Front Panel

Chassis

Accessory

Wall Sleeve

Accessory

Outdoor Grille

Wall Sleeve

Adapter

PTAC - Heat Pump and Electric Heat models_Prod Specs

Rearward Slope

Outside Wall

1/4" Slope

Inside Wall

Specifications

subject to change.

Product Dimensions

Height
Width
Depth
Max. Wall Thickness

Manufacturer

Wall Sleeve Part Number

General Electric

Amana
Trane

Friedrich

16"
42"
13-13/16"
13-13/16"

Metal Sleeve RAB71

Plastic Sleeve RAB77
Metal Sleeve WS900B
Metal Sleeve SLV149
T-Series Metal 11-1/2-in. Deep

Wall Sleeve
Standard-Depth Wall Sleeve

16 X 42 X 13-3/4-in. PXWS

Wall Cutout Dimensions

Height
Width

16-5/16"
42-3/16"

Plug Type (NEMA)

6-20P

PTAC Specifications

Product Shipping Weight (approx.) – 126 Lbs.

An electrical supply with grounded three-prong receptacle is required.

The power supply circuit must be installed in accordance with current

edition of National Electrical Code (ANSI/NFPA 70)

and local codes & ordinances.

Voltage Rating – 230V / 208V / 60 Hz / 20 Amps

Amps @ 230/208V Volts = (Cool) 2.8 / 3.0 Amps / (Backup Electric

Heater) 13.2 / 12.2 Amps / (Heat Pump) 2.4 / 2.5 Amps

Always consult local and national electric codes.

Recommended Circuit Breaker – 20 Amps

Unit equipped with 230/208V 3-wire power supply cord, NEMA plug

type 6-20P, approximately 66" long.

In order for condensate water to drain properly inside the unit, the

sleeve must be installed properly: Level from right to left with a slight

1/4" rearward pitch from the indoor side to the outdoor side as shown in

the illustration above. Refer to the Installation Instructions on the web.

The drain kit listed on the Frigidaire® PTAC Accessories page can

be used for an internal or external drain. This applies to new and

replacement installation.

New Installation

For new installation, Frigidaire® PTAC Sleeves are available and

recommended for proper installation. See accessories pages for

sleeve options.*

Standard PTAC installation requires 13-13/16" maximum wall thickness,

unless a wall sleeve is used.

If the PTAC unit protrudes more than 4", then it is suggested that it be

installed with a subbase. See accessories pages for subbase options.

Replacement Installation

When replacing existing PTAC with new unit, refer to Product

Installation Guide on web to identify existing wall-sleeve manufacturer

and size compatibility. If proper installation and slope are suspect,

then correct installation of Frigidaire® PTAC Sleeve options

recommended.

For any sleeve retrofit application, be sure that the foam seals

(factory-installed on the tube sheets) provide a good seal between

the grille and the outdoor coil tube sheets. These foam seals provide

a barrier that stops air from the inside mixing with air on the outside

(known as air recirculation).

Using Frigidaire® wall sleeve with Non-Frigidaire grille requires

installation of an Accessory Baffle Kit, which ensures a good seal

between the unit and exterior grille to prevent air recirculation. Air

recirculation is a large contributor to performance loss and premature

damage to major components.

Note: For planning purposes only. Refer to Product Installation Guide

on the web at frigidaire.com for detailed instructions.

*See Frigidaire® PTAC accessories pages attached for optional accessories.

USA

10200 David Taylor Drive

Charlotte, NC 28262

1-866-942-1567

frigidaire.com

CANADA

5855 Terry Fox Way

Mississauga, ON L5V 3E4

1-866-942-1567

frigidaire.ca

FRP77PTT2A 08/11

© 2011 Electrolux Home Products, Inc.

Printed in the U.S.A.

Packaged Terminal Air Conditioner (PTAC)

FRP77PTT2A

Air Conditioner / Heat Pump / Backup Electric Heater