09.4.28 11:46:27 AM
AC Line Voltage:
Single phase 120V, 60Hz, AC only
AC Power Required:
1600W 14.2 amps. (for FGMV173QF, FGMV173QB
Output Power*:
1000 W
Frequency:
2450 MHz (Class B/Group2)**
Outside Dimensions:
29 /8”(W) x 16 / ”(H) x 15
1
/32”(D)
Cavity Dimensions:
20
”(W) x 9
7
/16”(H) x 14 / 32”(D)
Microwave oven Capacity***:
1.7 Cu.Ft.
Cooking Uniformity:
Turntable
Weight:
Approx. (net) 61.7 lb, (gross) 28.0 lb
Work/Night Light:
2 bulbs 30w each (incandescent light bulbs)
Oven Light:
1 bulb 30w (incandescent light bulbs)
SERVICE CALL CHECK
SPECIFICATIONS
Please check the following before calling for service:
Place one cup of water in a glass measuring cup in the microwave oven and close the door securely.
Operate the microwave oven for one minute at HIGH 100%.
A Does the microwave oven light come on?
YES ____
NO ____
B Does the cooling fan work? (Put your hand on the louver above the
.)
YES ____
NO ____
C Does the turntable rotate? (It is normal for the turntable to turn in either direction.)
YES ____
NO ____
D Is the water in the microwave oven warm?
YES ____
NO ____
If “NO” is the answer to any of the above questions,
please check electrical outlet, fuse and/or circuit
breaker. If they are functioning properly, CONTACT
YOUR NEAREST ELECTROLUX AUTHORIZED SER-
VICER.
A microwave oven should never be serviced by a
“do-it-yourself” repair person.
*
The International Electrotechnical Commission’s standardized method for measuring output wattage. This test method
is widely recognized.
** This is the classification of ISM (Industrial, Scientific and Medical) equipment described in the International Standard CISPR11.
*** Internal capacity is calculated by measuring maximum width, depth and height. Actual capacity for holding food is less.
In compliance with standards set by:
FCC
- Federal Communications Commission Authorized.
DHHS -
Complies with Department of Health and Human Services (DHHS) rule, CFR, Title 21, Chapter I, Subchapter J.
NHW
- Department of National Health and Welfare of Canada.
- This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc.
- This symbol on the nameplate means the product is listed by Underwriters Laboratories, Inc. for use in
USA or Canada.
NOTES
very rapidly, check Demonstration Mode on page 2
and cancel.
/W/Q/M)
/
15 16
13
7
13 32
3
If time appearing in the display is counting down
Control Panel
7
2